b. Heat/Cool Control, this feature set the system is under Heating or Cooling control and
also set the system starting delay enable or disable. Use SELECT button to select Heating
or Cooling control: "Ht" for Heating and "CL" for Cooling and as figure shown below.
Heating Control
Cooling Control
Press SET button to confirm and enter the system starting delay enable or disable setting.
Use SELECT button to select the system starting delay "d:oN"-enable or "d:oF"-disable
and as figure shown below.
Press OK button to save quit this setting.
Heating Control
Cooling Control
3.
Temperature Setting
This Unit allow 4 preset temperatures: Comfort, Semi-Comfort, Economic and Anti-Frozen.
Please refer the figures shown as below:
Press and hold TEMP button for 3 seconds to enter. Use TEMP Button to select preset
temperature for setting. Press UP or DOWN button to adjust temperature setting. Press
TEMP button to save this setting and enter next temperature setting.
Press OK button to save quit this setting