3. DÉCLARATION DE CONFORMITÉ
La présente déclaration atteste que le système mentionné ci-dessous est en conformité avec les exigences
essentielles des directives 2014/30/EU et 2014/32/EU.
Description du système :
Type :
Fabricant :
Vibration
OIML R21, A.5.4.4.1 with testing according to IEC 68-2-64:
Testing was carried out in three mutually perpendicular axes for 0.5 hours in each direction and the taximeter was
connected to power during testing.
Dry Heat
OIML R21, A.5.4.1 with testing according to IEC 60068-2-2, but with the duration 16h and the highest temperature
+55°C. The test object was connected to power during the test.
Cold
OIML R21, A.5.4.1 with testing according to IEC 60068-2-2, but with the duration 16h and the lowest temperature
-25°C. The taximeter was not connected to power during testing.
Cyclic damp heat
OIML R21, A.5.4.2 with testing according to IEC 60068-2-30, with the following climate sequence:
(a) The first 3 hours - temperature rise from the specified low (25°C and 65%Rh);
(b) Temperature maintained at the specified high (+55°C and at least 93%Rh) until 12 hours from start of the
cycle;
(c) Temperature lowered from the specified high to the specified low (+25°C and at least 95%Rh) within the next
3-6 hours;
(d) Temperature maintained at the specified low until the 24-hour cycle is completed.
Emission
EN 55022, Class B
Immunity
OIML R21 A.5.4.5.1 Radiated immunity, according to IEC 61000-4-3, 24V/m
OIML R21 A.5.4.5.2 Injected RF immunity, according to IEC 61000-4-6, 24V
OIML R21 A.5.4.6 Electrostatic discharge, according to IEC 61000-4-2, 6kV CD/ 8kV AD
OIML R21 A.5.4.7.1 Automotive transient immunity on supply lines, according to ISO 7637-2, Pulse 1 ,2a, 2b, 3a,
3b, 4, 5 level 4
OIML R21 A.5.4.7.2 Automotive transient immunity on signal lines, according to ISO 7637-3, Pulse 3a, 3b, level 4
Le système a été testé conformément à ces normes par l'institut suédois RISE Research Institutes of Sweden AB.
Toutes les exigences sont remplies.
Certificat d'examen type CE :
Certificat décision d'évaluation :
Le produit dispose du marquage CE depuis 2008.
Signature :
La signature autorisée pour cette déclaration, au nom du fabricant, et la personne responsable basée dans la zone
de l'UE, sont identifiées ci-dessous.
Helsinki le 3 mars 2020
Börje Nummelin
Directeur général
Semel Oy
Document nr 73541G FR
16.12.2014 / © Semel Oy
FR3000
Système de taximètre
C30, TM6000, FR3000
Semel Oy
Valimotie 21
FIN-00380 HELSINKI
No. 0402-MID-50 23 02
No. 0402-MID-50 23 01
v.2
P a g e