4
| English
ENGLISH
SAFETY MEASURES
Read carefully the operating instructions
before assembling and starting. The appli-
ance must not be used by operators who
are not thoroughly acquainted with the
instructions handbook (operating instruc-
tions). Moreover, the appliance must not be
used by persons under the age of 16.
The user is liable towards third parties in the area
f
where the appliance is in operation.
Before starting it is necessary to make sure that
f
the necessary electrical protection measures, are
provided by means of a test carried out by a spe-
cialist.
While the pump is operating no operators
have to be in the liquid to be pumped.
The pump may be connected only by means
of a safety switch for fault currents, with
a rated opening current up to 30 mA and
a socket with an earth contact installed in
compliance with the regulations. Protec-
tion: at least 10 Amps.
Operation in swimming pools and garden ponds is
not recommended.
For other operation, the provisions in conformity
with the standard VDE 0100 part 702 must be re-
spected.
CAUTION: Before checking, unplug the
pump from the mains!
Replacing the power supply cable requires using
f
special tools and therefore you must address to
the authorized after-sales service.
The noise (continuous equivalent in dbA) of the
f
motor-driven pumps is less or equal (≤) to 70 dbA.
The voltage indicated on the pump' s rating plate
f
must correspond to the available mains voltage.
The temperature of the liquid conveyed must not
f
exceed 35°C.
Never attempt to lift or move the pump by stretch-
f
ing the power-supply cable whilst it is plugged into
the mains.
Make sure that the plugged electrical connections
f
are in an area safe from flooding and are protect-
ed from humidity.
Before use it is necessary to check that the plug
f
and the mains connection line are not damaged.
Unplug from the mains before performing any
f
work on the pump.
Avoid directly exposing the pump to the jet of water.
f
The user is responsible for complying with the lo-
f
cal regulations concerning assembly and safety.
The user by taking appropriate measures (e.g. install-
f
ing an alarm, reserve pump and the like) will have to
exclude the possibility of indirect damage caused by
flooding premises due to failure of the pump.
In the event of the pump failing, repair work may
f
only be carried out by the repair workshops of the
technical service. Only genuine spare parts must
JET 500 | JET 750 | JET 1000L
be used.
It is notified that in conformity with the law on
f
product liability we cannot be held responsible
for the damage caused by our appliance:
1. Because of improper repairs not carried out by
the personnel of the assistance points autho-
rized by us; or
2. If genuine spare parts are not used to replace
parts; or
3. If the indications and provisions given in the
instructions handbook are not complied with.
The same provisions hold for the accessories.
RESISTANCE
This pump should not be used to convey inflam-
mable, combustible or explosive liquids.
TECHNICAL DATA
Article Number
Model
V
Voltage
Hz
hp
Output power
W
Input power
W
Sound power
dB(A)
level
Max pressure
bar
Max head
m
Max flow
m
/h
3
1
inch
DN
2
inch
Stator length
mm
Weight
Kg
Motor
Speed of rota-
rpm
tion
Protection
Insulation Class
Continuous Duty
Internal Thermal
Protector
USE
For irrigation and watering of lawns, gardens, vege-
f
table patches, etc.
42924
42925
42926
JET
JET
JET
500
750
1000L
220-
220-
220-
230
230
230
50
50
50
0,50
0,75
1,00
370
550
750
500
750
1000
75
75
75
4,20
4,60
5,00
42
46
50
2,4
2,7
3,3
1
1
1
1
1
1
63#
71#
71#
L70
L62
L80
10,8
12,15
14,45
2.850
2.850
2.850
IP44
IP44
IP44
B
B
B
S1
S1
S1
✓
✓
✓