Service & Maintenance; Engine Switch - Ferm FGG-900 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
GB
For general use you can use an "all
temperature" oil 10W-30
≤0°C
0°C – 25°C
25°C – 35°C
≥ 35°C
Filling up the tank
Use petrol mixture only
Remove any powercords
Turn power switches off
Do not overfill – leave air gap at top of fuel
level
Always screw down fuel cap
Clean up any spilled fuel
Do not smoke while operating the generator
Always use caution!
Starting the generator
Fig. 1 + 3 + 4
1. Turn on fuel tap (8).
2. Turn on engine switch (5).
3. Move choke lever (6) to closed position
(to restart a warm engine, leave the choke
lever in open or half-open position).
4. Pull slowly on the starter cord until it
engages, then pull sharply to start the
engine (7).
5. Allow the engine to run until it warms up,
and then move the choke lever to the open
position (6).
Using the AC Output (230 V)
Start the generator.
Plug in the electrical appliance plug.
Stopping the generator
Fig. 1 + 4
1. Unplug all cords (5)
2. Turn engine switch to "OFF" (5)
3. Turn off fuel tap (8)
4. SERVICE & MAINTENANCE
PERIODIC MAINTENANCE
Daily (pre-operation check)
Check fuel hose for cracks or other
damage. Replace if necessary.
6
SAE#10
SAE#20
SAE#30
SAE#40
Check exhaust-system for leakage.
Retighten or replace gasket if necessary.
Check choke operation.
Check recoil starter operation.
3 Months or 50 hrs
Check condition of spark plug. Adjust gap
and clean. Replace if necessary.
6 Months or 100 hrs
Clean fuel tap and fuel tank filter. Replace if
necessary.
Check fittings and fasteners. Replace if
necessary.
12 Months or 300 hrs
Contact a specialized service centre to
check the valve clearance.
Check the fan of the cooling system for
damage.
Spark plug inspection
Fig. 2
Disconnect the spark plug cap, and remove
any dirt from around the spark plug area.
Remove spark plug (10) with the plug
spanner supplied.
Inspect the spark plug. It should be a tan
colour.
Measure the gap (distance contact point)
with a suitable gauge. The gap should be
0,7 - 0,8 mm. Correct the gap, if necessary,
by carefully bending the side electrode.
Replace the spark plug if the electrodes
are worn, or if the insulator is cracked or
chipped.
Install the spark plug carefully, by hand, to
avoid cross-threading.
Place the spark plug with correct torque: 20
Nm.
Attach the spark plug cap.
Exhaust screen
Wait for exhaust to cool.
Exhaust screen may be blocked up with
carbon deposits.
Undo the screw cap and remove the
exhaust screen.
Clean the screen with a wire brush and refit.
Replace exhaust screen if damaged.
Ferm