System diagnostics
1 x Beep
2 x Beep
3 x Beep
With flush: system in order
No flush: problem with magnetic valve or
water supply
To fix the problem:
•
Check the connection between the electronic
(control) system and the magnetic valve
•
Check the water connection
•
Check the magnetic valve
Sensor problem
To fix the problem:
•
Check the connection between the electronic
(control) system and the sensor
•
Check the sensor
•
Check the electronic (control) unit
Weak batteries
To fix the problem:
•
Replace the batteries
(battery operation optional)
04 English
200 S
200 W
200 S D
200 W D
49