THERMASREG
Mechanical temperature controllers ⁄ contact thermostats THERMASREG
controlling and limitation of temperatures at pipes or vessels, e.g. in connection with hot-water or floor heating systems. The contact temperature
controller ALTR is built as one - step device, as adjustable temperature controller TR (with external setting) or as adjustable temperature monitor
TW (with internal setting).
TECHNICAL DATA
Switching capacity:
(Contact load)
Contact:
Housing:
Housing dimensions:
Cable gland:
Housing temperature:
Tolerance:
Design principle:
Process connection:
Electrical connection:
Protection class:
Protection type:
Standards:
FUNCTION
THERMASREG
®
ALTR 1 ⁄ 3 ⁄ 5 ⁄ 7
Type ⁄ WG01
ALTR 1 ⁄ 3 ⁄ 5 ⁄ 7
A LT R -1
A LT R - 3
A LT R - 5
A LT R -7
Extra charge:
ALTR 1 ⁄ ALTR 3 ⁄ ALTR 5 ⁄ ALTR 7
24 ... 250 V AC + 10 %, 16 A, cos ϕ = 1.0
24 ... 250 V AC + 10 %, 1.5 A, cos ϕ = 0.6
at 24 V AC min. 150 mA
dust-proof switch block unit as potential-free
single-pole changeover contact
plastic, UV-resistant, material polyamide, 30 % glass-globe reinforced,
colour traffic white (similar to RAL 9016)
108 x 70 x 73.5 mm (Thor 2)
M 20 x 1.5; including strain relief
–35...+65 °C
T
± 5 K; T
± 5 K
min
max
torsion meter with liquid filling
endless strap with metal tightener (included in the scope of delivery),
Ø = 13 - 92 mm (¼ - 3"), L = 300 mm
2
0.14 - 2.5 mm
via terminal screws
I (according to EN 60 730)
IP 65 (according to EN 60 529)
CE conformity, EMC directive 2014 ⁄ 30 ⁄ EU,
low-voltage directive 2014 ⁄ 35 ⁄ EU
Heating: The preset setpoint (scale value) is equivalent to the switch-off value of the heating.
The switch-on value is lower by the amount of operating difference.
Contact 2 - 3 breaks when temperature rises to the preset value.
Cooling:
The preset setpoint (scale value) is equivalent to the switch-on value of the cooling.
The switch-off value is lower by the amount of operating difference.
Contact 1 - 2 closes when temperature rises to the preset value.
Surface contact temperature controllers
Temperature
Thermal Operating
Range
Difference (fixed) approx.
–35... +35 °C
5 K (± 1 K)
0... +60 °C
5 K (± 1 K)
0... +90 °C
5 K (± 1 K)
0...+120 °C
5 K (± 1 K)
U = Internal setting (TW), e. g. ALTR - 1 U
®
ALTR with switching output (two-position controller) for monitoring,
Max. Capillary
Temperature
+60 °C
+75 °C
+120 °C
+130 °C
Rev. 2021 - V14
Connecting diagram
2
1
Cooling
Heating
3
Item No.
TR (External setting)
1102- 1030-110 0-100
1102-1030- 1100- 300
1102- 1030- 1100-400
11 02-1030- 1100- 500
ALTR 1
ALTR 3
ALTR 5
ALTR 7