2.4.1 Other connections
The following image shows the remaining connection options of the Omnicharge
charger.
① A remote on/off switch (SPST) can be connected to the 'REMOTE SWITCH' terminals.
When the switch is closed the charger is active and when the switch is opened the
charger jumps to a standby (sleep-) mode. Before installing the remote wiring, please
remove the pre-installed wire link in the removable male connector. The minimum
electrical specifications for the remote switch are 5V and 5mA.
② The DC output fuses are accessible for easy replacement in case these are blown due
to an accidental reverse polarity connection of the battery. Always replace the fuses
with the correct types. These are:
• OC
2
12-40 / 2x 30Amp ATO blade
• OC
2
12-60 / 3x 30Amp ATO blade
• OC
2
24-20 / 2x 15Amp ATO blade
• OC
2
24-30 / 3x 20Amp ATO blade
③ The optional QuickLink interface kits can be used to configure and readout the charger
using 'Dashboard 2' for Windows (USB / RS232) or 'Dashboard Mobile' for iOS and
Android (Bluetooth).
11
2
battery