Replacing the plug fuse (12/24 V)

➤ Pull the adapter sleeve (fig. 9 4, page 5) off of the plug.
➤ Unscrew the screw (fig. 9 5, page 5) out of the upper half of the housing
(fig. 9 6, page 5).
➤ Carefully lift the upper half of the housing off from the lower (fig. 9 1,
page 5) half.
➤ Take out the contact pin (fig. 9 3, page 5).
➤ Replace the defective fuse (fig. 9 2, page 5) with a new fuse that has the
same rating (10 A).
➤ Re-assemble the plug in the reverse order.
7.13

Replacing the light PCB

➤ Disconnect the power supply to the device.
➤ Pry out the transparent cover with a screwdriver (fig. 0 1, page 5).
➤ Unscrew the PCB mounting screws (fig. 0 2, page 5).
➤ Pull out the plug from the PCB (fig. 0 3, page 5).
➤ Replace the defective light PCB with a new one.
➤ Fit new PCB using reverse of removal instructions.
➤ Press the transparent cover back into the housing.
➤ Reconnect the power supply to the device.