Storch Keko 200 Mode D'emploi page 49

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Helpful tips for malfunctions:
1)
Fault: The machine does not switch on or stops and does not restart..
Cause: No power supply.
Solution:
1. Make sure the "ON/OFF" switch is is set to "ON (I)";
2. Check to make sure the power plug is working and has been inserted correctly into a suitable socket;
3. Check any extension cables, cable reels and the power socket to make sure they are working properly;
4. Check the power supply.
2)
Fault: Tripping of the resettable thermal switch.
Cause: Current overload and/or short circuit.
Solution:
1. Set the "ON/OFF" switch to the "OFF (0)" position and get an electrician to determine the cause of the current over-
load / short circuit.
2. Actuate the push button of the overload switch.
3. Before restarting the machine wait a few minutes and allow it to cool down.
3)
Fault: The compressor starts frequently without a tool being used.
Cause: Leaking connections / couplings or leaks in the pressurised area of the machine.
Solution:
1. Check the pressurised area for damage.
2. Check the tightness of the connections, the air hose and the tool.
4)
Fault: No air comes from the tool.
Cause: The tank is not pressurised. Incorrect adjustment of the output pressure. The tool is damaged.
Solution:
Switch on the machine and wait until the tank has been filled. Check the pressure on the manometer. Check whether
the value displayed on the manometer is greater than 0 bar. Check the tightness and functionality of the tool.
5)
Fault: Pressure in the air tank drops.
Cause: Leaks in the air hose, in the air lines, on the connections, on the tool or in the pressurised area.
Solution:
1. Check the tightness of the pneumatic system.
2. Check the air lines, hoses, connections / couplings and tools for leaks.
3. Make sure the condensate drain valve is closed properly.
6)
Fault: Safety valve trips.
Cause: Pressure switch is faulty.
Solution:
Replace the pressure switch.
7)
Fault: Loss of air pressure on the valve of the pressure switch when the compressor is in stand-by.
Solution: Check to see if the valve is worn or dirty.
8)
Fault: The machine vibrates and/or emits a loud noise.
Cause: Mechanical break.
Solution: Contact a STORCH service partner.
9)
Fault: Frequent activation and low output.
Cause: Air filter dirty.
Solution: Clean the filter.