Temperature Sensor (Option, can be connected):
For automatic adaptation and correction of the charging voltage to the battery tem-
perature (temperature compensation)�
Mounting: The thermal contact of sensor and battery »Main I« (inside temperature)
should be well� Thus, it should be screwed down to the negative pole or positive
pole of the battery� It is also possible to fasten it at the sidewall centre of the battery
casing� Ensure that the installation place is not influenced by any source of heat
(motor block, exhaust, heater etc�)�
Connection: Connect the temperature sensor to the terminal by means of a 2-pole
cable (cable cross section 0�5 – 1�5 mm²)� The polarity and cable length is of no
importance� The solar controller recognizes the sensor automatically�
Effect: The temperature-dependent charging voltage of battery I will be adapted
automatically to the battery temperature� The temperature sensor measures the
battery temperature� In case of low temperatures (winter operation), the charging
voltage will be increased in order to improve and accelerate full charging of the
weak battery�
LCD meter ( Option, can be connected):
The LCD display indicates the following values: Battery voltage, charging current,
charging capacity, stored capacity and energy (V, A, W, Ah, Wh)
Safety Mode:
The solar controller recognizes automatically a missing sensor, cable break or
short-circuit of the sensor lines, as well as unreasonable measuring values� In that
case, it will switch automatically to the usual charging voltage rates of 20 °C / 25 °C
being recommended by the battery manufacturers�

PILOT LAMPS

Battery Full
(Battery fully charged, green):
If it is lighting:
Battery (batteries) has (have) been charged to 100 %, finished�
>80 % (green)
851001
If it is lighting:
Battery has been charged almost fully� Solar controller is still
in the charging constant voltage
>80 % (green)
851002
If it is lighting:
Battery has been charged almost fully� Solar controller is still
in the charging constant voltage
if it is flashing:
frequency 1time/s: controller over-heat
frequency 2times/s: battery over-voltage, or PV over-voltage
Charge
(only
If it is lighting:
Charging
Off:
Solar power is insufficient
If it is flashing:
frequency 1time/s: controller over-heat
frequency 2times/s: battery over-voltage� or PV over-voltage
Carbest Bluetooth Dual MPPT Battery Solar Controller | 851001/851002
) green:
851001
16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

851002

Table des Matières