Command
OFF
Turns the relay output off (disables AUTO)
#
ON
Turns the relay output on (disables AUTO)
#
STATUS
Finds out the current status
#
AUTO
Activates the AUTO function at the threshold programmed previ-
#
ously
Note: the commands sent must consist exclusively of capital letters and with no spaces.
Troubleshooting
If a fault arises, the error signalling LED will flash red. Count the number of flashes to identify the error code as
indicated in the table below:
Flashing code
1
GSM signal is not detected
2
The SIM card is protected by a PIN code
3
The SIM card is not present
4
The SIM card not work
5
System error: try restarting the device
6
The SIM card is protected by a PUK code
Technical Data
Communication
Power suppy
Output
Input
Main characteristics
Certifications
Current drawn
(typical values)
Software Requirements
The following table lists the operating systems supported by the software telltask 1C1.
Operating system
Windows 7
The .NET Framework Client Profile is not supported on IA-64-based (Itanium) systems.
Windows 8
For all platforms, we recommend that you upgrade to the latest Windows Service Pack and critical updates avail-
able from the Windows Update Web site to ensure the best compatibility and security.
Windows 10
Description
•
UMTS/HSPA/GSM 900Mhz ,1800MHz, 2100Mhz
•
Supply voltage: 5.3 -12V DC
•
Current: Imax = 800mA
•
The device must be powered by a power source limited to 24VA.
Power supply protected against reversed polarity
•
1 Relay SPDT
•
0,5A, 250V AC (Resistive);
o
o
1A, 30V DC.
•
1 digital input (VCC), potential free
•
Degree of infiammability: UL94V-0
•
Protection degree: IP20
Standard operating temperature: -5°C to +45°C
•
Max conductor size: 2,5mm
•
USB programming port
•
2014/53/EU (RED)
•
2014/30/UE (EMV)
•
•
2014/35/UE (LVD)
•
FCC/CE/TELEC/KCC/SRRC/IC/NCC
Standby 40mA
Sending\Receiving SMS 200mA
Description
2
NOTE
Example
Response
OFF
OFF
#
ON
ON
#
STATUS
Current sta-
#
tus
AUTO
Th: 20C
#
17
17