Safety And Protection Devices; Troubleshooting And Repair - ITM Italia SUNBEAM 20 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
4.

SAFETY AND PROTECTION DEVICES

Limiter thermostat 9 (Fig.1 - 2 - 3). This cuts off the electric power supply in the event of
overheating. If the temperature limiter has tripped, let the heater cool down and attend to the
fault.
5.
MAINTEINANCE
5.1 WARNING AND PERIODICAL CHECKS
Maintenance may only be carried out by suitably skilled personnel. Clean the heater at
regular intervals, since dust and dirt may give rise to overheating and the consequent risk
of fire.
6.

TROUBLESHOOTING AND REPAIR

TROUBLE
CAUSE
THE HEATER
BURNED-OUT ELEMENT
IS ON BUT
DOES NOT
HEAT
REGULATOR THERMOSTAT
BROKEN
THE HEATER
LIMITER THERMOSTAT
DOES NOT
TRIPPED
STAR
BROKEN CONNECTIONS
THE HEATER
BLOCKED AIR INTAKE
PRODUCES
VERY LITTLE
AIR
THE ELECTRIC MOTOR IS
NOT WORKING TO ITS
FULL CAPACITY
GB
REMEDY
REPLACE
REPLACE
LET THE HEATER COOL DOWN
DISCONNECT THE PLUG AND CHECK CONNECTIONS
REMOVE ANY OBSTRUCTINS FROM THE AIR
PASSAGE
REPLACE
3

Publicité

Table des Matières
loading