CHECK THE GAS TYPE THE DEVICE IS ADJUSTED FOR
Our appliances are certifi ed and regulated the natural gas (see technical plate). Conversion or adaptation to
a diff erent type of gas must be performed by authorized personnel. Nozzles for diff erent types of gas are in a
bag provided with the gas cooker and are marked in hundredths of mm (table of technical data pipes).
Nozzle replacement and pressure adjustment
Proceed as follows when replacing the main burner nozzle:
1) remove the control buttons from the front panel (fi g.1, note 1)
2) disassemble the front panel (fi g.1, note 2)
3) we recommend you also disassemble the rear panel (if possible) for easier access (fi g.1, note 3)
4) Adjust the air intake for the relevant gas according to table „TECHNICAL DATA"
Important:
After what was done adjusting the appliance to another type of gas, it is necessary to change the gas
indicated on the technical plate located in a visible location on the back of the device.
Adjusting fl ame at reduced performance „SAVING"
Flame at reduced performance „SAVING", can be set with screw placed in the valve body (note. 1, fi g. 5)
positioned next to valve shaft
For adjusting proceed as follows:
-
Remove the control knob (note. 1, fi g. 4) pulling towards you
-
Adjust the fl ame through hole with fl at screwdriver
5
5
8
1
1
HOLE FOR FLAME
HOLE FOR FLAME
ADJUSTING
ADJUSTING
1
1
4
4