Dimensions And Clearances; Technical Data; Installation; Opening Cable Knockouts (Fig. 4) - Galletti MCI 004H Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27

3 - DIMENSIONS AND CLEARANCES

For dimensions see fig. 1
MCI
A
004_ 1Ph
908
006_ 1Ph
908
008_ 1Ph
908
012_1Ph
908
015_1Ph
908
012_3Ph
908
015_3Ph
908
Minimum installation clearances in mm are shown in fig.2 (single installation) and fig. 3 (serial installation)
NOTE: The height of the obstacle at both front and rear side should be lower than the height of the outdoor unit.

4 - TECHNICAL DATA

Unit
Compressor Type
Water pump speed
Capacity
Expansion vessel
Nitrogen precharge pressure
Net water volume
Water connections
Maximum water pressure

5 - INSTALLATION

Before installation, check strength and horizontality of the
base so that abnormal sound does not generate.
According to the dimensions and clearances, fix the base
firmly with the anchor bolts (Anchor bolt, nut: M10 x 2 pairs).
If the outdoor unit is installed in a very windy place, protect
the fan with a wind protection screen and check that it works
correctly.

5.1 - Opening cable knockouts (Fig. 4)

There is a pre-cut part that can be removed for running wires.
Do not remove the unit front panel for easier drilling of the
knockouts. The pre-cut section of the sheet can be removed
by punching the 3 connection points along the line first
using a chisel and finally with pliers (see fig. 4).
When the cable knockout is open, remove the burrs and fit
the cable protective bush supplied with the unit for cable
protection.

5.2 - How to remove the front panel (Fig. 5)

1.
Remove screws of the front panel (See fig 5).
2.
Pull the front panel downward with the handle.
B
C
D
821
326
350
821
326
350
821
326
350
1363
326
350
1363
326
350
1363
326
350
1363
326
350
MCI
004H
006H
Rotary DC Inverter Tecnology
Variable speed
l
2
kPa
200
l
1
1
1''M
kPa
300
All copying, even partial, of this manual is strictly forbidden
E
F
G
87
356
466
87
356
466
87
356
466
174
640
750
174
640
750
174
640
750
174
640
750
008H
012H
015H
004X
N.A.
3
N.A.
N.A.
1.2
2.5
2.5
0.8

5.3 - Drain hose and base pan knockouts (Fig. 6)

See fig. 6.
In case of draining through the drain hose, attach the drain
nipple (A) and use the drain hose (Inner diam.: 16mm) sold in
the market. When there is a possibility of freezing of drain at
the cold district or a snowfall area, be careful for drainage
ability of drain.
The drainage ability increases when knockout holes on the
base pan are opened. (Open the knockout hole to outside
using a soft-faced hammer (B), etc.).

5.4 - Operating limits (Fig. 7/8)

Operation in cooling: See fig. 7
NOTE: For the MCI004_ and MCI006_ units use a minimum
External Air Temperature of +5 °C.
(- -MCI006_ ,- . -MCI004_ )
Operation in heating: See fig. 8
H
L
kg
40
60
57
40
60
61
40
60
69
44
69
104
44
69
112
44
69
116
44
69
116
006X
008X
012X
015X
0.8
1
2.3
2.3
RG66012647
17

Publicité

Table des Matières
loading

Table des Matières