Capteur d'énergie radio simple Mini
Transmit apparent power
Transmit absolute active ener-
gy
Transmission interval
Rel. threshold value, effective
power
Abs. threshold value, effective
power
Suppression length, effective
power
Averaging length
Information window
During channel selection in the Information window, the following values are displayed.
Display value
Voltage
Current
32581512
10864964
On, Off
Basic setting: On
On, Off
Basic setting: On
1 ... 60 min
Basic setting: 15 min
1 ... 50 %
Basic setting: 10 %
0 ... 2000 W
Basic setting: 1 W
0 ms ... 300 s
Basic setting: 0 ms
0.2 ... 300 s
Basic setting: 1 s
Explanations
Displays the current voltage value.
Displays the current current value.
11.04.2017
Transmits the current appa-
rent output value.
Transmits the cumulative va-
lue of the active energy. If ne-
gative values are displayed,
then effective energy is fed in,
e.g. via a photovoltaic system.
The current consumption data
is transmitted at the interval
set here at the latest. Changes
to the effective power cause
fresh transmission, however
only after one minute at the
earliest.
The transmission of the
consumption data can be cou-
pled to the change in effective
power. The basis is always the
most recently transmitted ef-
fective output value. If the per-
centage change entered here
is exceeded, then all the mea-
sured values are resent.
A lower threshold value of the
effective power can be ente-
red here, to avoid frequent
transmission in the lower po-
wer range. Event-controlled
transmission is only active
above this threshold value.
Triggers for event-controlled
transmission are often switch-
on and switch-off operations.
In order to avoid incorrect
measured values due to
switch-on peaks, this parame-
ter can be used to enter a sup-
pression period. The measu-
red values are only transmit-
ted if the effective power is still
above or below the relative
threshold value after the set
time.
In the case of effective power,
it is not the current value
which is transmitted, as with
other measured values, but
the average value. It is pos-
sible to set the period for ave-
rage value formation here.
6/8