Installation class: 1.
WARNING: This appliance must be installed by professionally qualified
personnel.
The installation must be carried out in conformity to the regulation in force (for
Italy: UNI 7131).
Place the stove on a horizontal surface respecting the instructions indicated in
the chapter of Safety Instruction .
Check that the gas pipe that you want to use is in accordance with the rules in
force in your country (for Italy: UNI 7140) and it has already assembled with the
pressure reducer with the characteristics described in the chapter of Safety
Instruction and in the technical data table.
Insert into the gas pipe a full mesh metal clamp suitable for LPG gas pipes .
To insert the gas pipe in the stove gas's connector on the back of the stove and
push it until the pipe is inserted up to the connector for at least 2cm .
Tighten the metal clamp in order to seal safely the rubber hose to the stove
connector.
Before assembling the cylinder, turn the burner valve's knobs clockwise until them
reach the closed position.
Place the gas cylinder in a stable and dry surface
Connect the pressure regulator already assembled to the gas pipe to the LPG
cylinder making sure you have correctly inserted the seal gasket supplied with the
cylinder.
Always use the new gaskets supplied together with the LPG cyclinder.
Tighten the regulator to the cylinder to prevent gas leakage.
Check that the gas hose is not twisting. In case, rotate the pipe in order that every
twist or curve is eliminated and the tube has a linear shape.
Turn the cylinder's valve knob until fully open in order to allow the gas LPG to
feed the stove.
Keeping the stove taps closed for fice minutes and check does not spread out
smell of gas before proceeding with the use of the stove.
To verify that the installation has been done successfully, pour soapy on the joints
of every connection. Any leaking will be well visible using this solution.
Attention: Never use a flame to check the Gas leaking.
Lightly press and turn counterclockwise the burner valve's knob according the
burner you want use.
Put a lighter close to the defined burner
Wait until the burner is fully switch ON and adjust the flame by turning the knob
clockwise or counterclockwise according your needs .
To make the temporary shutdown of the burner , turn the knob clockwise to the
OFF position.
After cooking , or before storing the product, turn OFF the burner by turning
clockwise the cylinder valve's knob tilli s close and wait for the complete extinction

(EN) INSTALLATION

(EN) LPG CYLINDER ASSEMBLY
(EN) PRODUCT'S USE