7.TROUBLESHOOTING
EN
PROBLEM/SOLUTION
Burners
The burners do not ignite with the ignition system
• The gas cylinder is empty ^
• Faulty regulator
• Burners clogged
• Gas hose or nozzles clogged
• The electrode cable is loose or disconnected from the electrode
• The electrode or cable is damaged
• The integrated igniter is faulty
• Incorrect electrode gap
The burner does not ignite with a gas igniter
• The gas cylinder is empty ^
• Faulty regulator
• Burners clogged
• Gas hose or nozzles clogged
Small flame or flashback (flame in the burner tube, whistling or perceptible whirring)
• The gas cylinder is too small
• Burners clogged
• Gas hose or nozzles clogged
• Wind
The gas valve knob is difficult to turn
• Integrated ignition system jammed ^
• Gas valve jammed
 Replace with a full cylinder
 Check or replace the regulator
 Clean the burners
 Clean the gas hose or nozzles
 Reconnect the cable
 Replace the electrode and the cable
 Replace it
 The electrode must comply with the
 Replace with a full cylinder
 Check or replace the regulator
 Clean the burners
 Clean the gas hose or nozzles
 Use a bigger cylinder
 Clean the burners
 Clean the gas hose or nozzles
 Use the barbecue in an area that is less
 Replace the gas valve
 Have your retailer replace the gas valve
150
burner, with a distance of 3 to 4 mm
between the end of the electrode and
the port on the burner. Realign the
electrode as required.
exposed to wind