Maxx Air 503/703 Exhaust fans listed in these instructions are designed for
use in the bathroom. Approved for installation above a tub or shower
enclosure when connected to a UL Listed GFCI protected branch circuit. Not
for use in kitchen.
503, 703 Exhaust Fans
SAFETY INSTRUCTIONS
WARNING: to reduce the risk offire,
electric shock, or injury to persons,
observe the following:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA) and
the American Society of Heating, Refrigeration and Air
Conditioning Engineers (ASH RAE) or local code authorities.
S. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter)- protected branch circuit.
8. NEVER place a switch where it can be reached from a tub or
shower.
CAUTION: for general ventilating use only! Do Not Use To
Exhaust Hazardous Or Explosive Materials Or Vapors.
TOOLS FOR INSTALLATION
�- �
• screwdriver
• keyhole saw or jig saw
• hammer
• wire cutters
• electric drill
• wire stripper
NVI
c®us
CERTIFIED
READ AND SAVE TH ESE INSTRUCTIONS. File with your important papers.
LEA V CONSERVE ESTAT INSTRUCCIONES. Archive/as con sus pope/es importantes.
LIRE ET CONSERVER CE MODE D'EMPLOI. Le classer parmi vos documents importants.
Los Ventiladores Aspiradores 503/703 de Maxx Air incluidos en estas
instrucciones, estan diseriados para uso en el bario. Estan aprobados para la
instalaci6n sabre la bariera o sabre el area encerrado de la regadera cuando
son conectados a una red de circuito protegida por GFI resgistrada por UL.
No son para uso en cocinas.
0
5 03, 703 Ventilador de Extraccion
INSTRUCCIONES DE SEGURIDAD
ADVERTENCIA: para reducir el riesgo de
lncendio, choque electrico o lesion es
observe las siguientes instrucciones:
1. Use esta unidad unicamente de la manera indicada por el
fabricante. Si tiene preguntas, dirfjase al fabricante.
2. Antes de darle mantenimiento o limpiar la unidad, desconecte la
electricidad en el panel de servicio y cierre el servicio desconectando
medios por los que sea posible encender accidentalmente. Cuando el
servicio de desconexion no se pueda asegurar, fije una advertencia
prominente, tal como una etiqueta, al panel de servicio.
3. El trabajo de instalacion y alambrado electrico debe ser hecho por
persona(s) competente(s) de acuerdo con todos los codigos
aplicables y estandares, incluyendo construccion que incluya
aplicaciones de incendio.
4. Se necesita suficiente a ire para la combustion apropiada y
expulsion de gases, a traves de la chimenea del equipo de
combustion para prevenir corrientes de a ire hacia adentro. Siga las
gufas del faricante de equipos de calefaccion y los estandares de
seguridad tales como los publicados porThe National Fire Protection
Association (NFPA) y American Society of Heating, Refrigeration and
Air Conditioning Engineers (ASH RAE) o las autoridades del codigo
local.
S. Cuando corte o taladre la pared o el techo no darie el alambrado
electrico ni otros servicios ocultos.
6. Los ventiladores entubados deben siempre tener ventilacion del
aire hacia afuera.
7. Si esta unidad se va a instalar sobre una bariera o regadera, deber
ser apropiadamente msarcada y ser conectada a una red de circuito
GFCI.
8. Nunca ponga un interruptor de pared que pueda ser alcanzado
desde la bariadera o regadera.
9. Apto para ser usado con rapido control de velocidad de estados
solidos.
ADVERTENCIA: jSOLO PARA VENTI LACl6N GENERAL! No use
esta unidad para extraer Materiales P eligrosos, Explosivos o
Vapores.
• wire nuts
HERRAMIENTAS PARA LA INSTALLACION
• safety glasses
• ruler or straightedge
• detornillador
• martillo
• taladr o electr ico • corta dor de alamb re
0
• sierra de punta a
• colectores de alambre
sierra para contornear
• gafas de proteccion
• deaforrador de a la mbre
• reg la a ta bil la recta
Les ventilateurs de ti rage 503/703 de Maxx Air sont conc;:us pour etre utilises
dans les salles de bains. Approuves pour installation au-dessus d'une
baignoire ou d'une cabine de douche lorsque branches
a
derivation protege par un disjoncteur de fuite
s'en servir dans une cuisine.
503,703 Ventilateurd'Evacuation
CONSIGN ES DE SECURITE
AVERTISSEMENT: pour limiter les risques d' incendie, de
commotion electique ou de lesion corporelle, respecter
les consignes de securite suivantes:
1. Ne se servir de cette unite que de la fac;:on prevue par le fabricant.
Si vous avez des questions, comm uniquer avec le fabricant.
2. Avant d'entretenir ou de nettoyer l'unite, couper le courant au
panneau de service et verrouiller le dispositif de sectionnement de
service afin d'empecher que le courant ne soit accidentellement
retabli. Lorsque le dispositif de sectionnement de service ne peut etre
verrouille, attacher solidement au panneau de service un dispositif
d'avertissement bien visible, par ex. une etiquette.
3. Les travaux d'installation et de cablage electrique doivent etre
effectues par des personnes qualifiees, conformement
codes et normes applicables, y compris les normes de construction
resistante au feu.
4. On a besoin de suffisamment d'air pour assurer une combustion
a
appropriee et !'evacuation des gaz
travers le tube de fumee
(cheminee) de l'equipement de chauffe, afin d'empecher le
refoulement de l'air. S'en tenir aux directives et aux normes de securite
du fabricant d'equipement de chauffe, telles celles qui sont publiees
par la National Fire Protection
Association (NFPA) et !'American Society of Heating, Refrigeration and
Air Conditioning Engineers (ASH RAE) ou les autorites locales
responsables de tels codes.
5. Lorsque l'on fait des coupures ou que l'on fore des trous dans un
mur ou le plafond, ne pas endommager les cables electriques et tout
autre service cache.
6. Les soufflantes canalisees doivent toujours etre mises
vers 'exterieur.
7. Si cette unite doit etre installee au-dessus d'une baignoire ou
d'une douche, elle doit etre marquee com me convenant
a
application et branchee
un circuit de derivation protege par un
a
disjoncteur de fuite
la terre.
a
8. NEJAMAIS installer un interrupteur
un endroit que l'on puisse
a
atteindre
partir d'une baignoire ou d'une douche.
9. Peut etre utilise avec des dispositifs de vitesse en etat solide.
ATTENTION: NE SE SERVIR DE CE PRODUIT QUE POUR LA VENTILATION
Gl:NERALE! Ne pas utiliser dans le but d'evacuer des materiaux ou des
vapeurs dangereux ou explosifs.
OUTILS REQUIS POUR L'INSTALLATION
a
• tournevis
• scie
guichet ou
• marteau
scie sauteuse
a
• foreuse electrique
• pince
denuder
• coupe-fil
a
un circuit de
terre homologue UL. Ne pas
0
a
tous les
a
l'air libre
a
cette
• capuchons de fil
• lunettes de protection
• regle ou regle droite

Publicité

loading

Sommaire des Matières pour Maxx air 503

  • Page 1 LEA V CONSERVE ESTAT INSTRUCCIONES. Archive/as con sus pope/es importantes. LIRE ET CONSERVER CE MODE D'EMPLOI. Le classer parmi vos documents importants. Les ventilateurs de ti rage 503/703 de Maxx Air sont conc;:us pour etre utilises Los Ventiladores Aspiradores 503/703 de Maxx Air incluidos en estas dans les salles de bains.
  • Page 4 1.800.433.1626. servicio de garantfa o informaci6n favor de visitat el sitio www.mymaxxair.com o Ila me al: THAN R-40 1.800.433.1626. Maxx Air is manufactured by Ventamatic, Ltd. For replacement parts, contact Ventamatic at www.mymaxxair.com or via telephone at 1-800-433-1626 PARTS DESCRIPTION PICTURE KEY Part No.

Ce manuel est également adapté pour:

703