USB port
Connect the USB external appliance to the USB port and switch it on. The USB port on the power inverter
provides a power supply of 5V DC for external USB devices.
The USB port on the power inverter is not designed for transferring data. Do not
connect memory sticks, MP3 player or similar data storage external appliances. Do
not connect any data transfer cable to the USB port.
Remote Port
Connect the remote unit to the remote connection port (L). Before using the remote unit, ensure the
main switch (G) is in "Position II".
WARNING! Do not open or disassemble the Inverter. Attempting to service the unit
yourself may cause the risk of electrical shock or fire. Please follow the safety
instructions when working on the device.
The LCD display indicates in case of an error the appropriate error code:
Error
Description
Code
Battery-overvoltage-protection: The battery voltage exceeds the permissible
E2
range. Check the battery !
Battery-undervoltage-protection: The battery voltage has fallen below the
E3
permissible range. The battery seems to be empty. Check the battery and
recharge when required.
Short-circuit- /over-power-protection: check if the 230V AC load exceeds the
E5
inverters power-limits or is short-circuited.
Overtemperature-protection: The inverter got too hot. Allow 10-15 minutes
E6
for the inverter to cool down, before putting it in operation again. Provide for
good ventilation.
Only at models PSI1000TX & PSI1500TX: PV-reverse-polarity-protection:
E7
Check if PV panels are connected with reversed.
Only at models PSI1000TX & PSI1500TX: PV-overcurrent-protection: The solar
panel seems to deliver too much power and exceeds the maximum PV-input-
E8
power of the inverter. Check your solar panel if it meets the requirements.
Wait 3 minutes before connecting the panels again.
If the device doesn't work at all, an internal fuse might be blown. This happens always for a reason.
Maybe there has been a short circuit, when connecting the inverter in wrong polarity. Don´t try to
replace internal fuses yourself. The inverter has to be checked by the manufacturer or by an