A
Fig/Abb 3
1
features
Right opening function electric lock.
Works on 8 – 12 V ~ continuous or alternating current.
Pulse system or tag control.
Reduced power consumption:
700 mA 8 / 12 V
Voltage: 12-V DC
Important: Terminal wire calibre:
• 1-25 metres: 2 x 6/10 wires,
• over 25 metres: 2 x1.5 mm2 wires (the whole length).
2
installation
The lock is supplied "right" mounted.
3
attachment of the electric lock
• Determine the position of the stirrup and the cylinder hole with the template.
Attention, to plan the space being enough for the passage of the antenna
of the receiver (B)
• Using the four screws supplied, fix the carrier to the gate. (C)
• Using the four screws, fix the electric lock to the carrier (D).
• To position the support blows up for the antenna around the cylinder, to
come to roll up the cable antenna inside (a single tour is enough). (E)
• Close the electric lock housing back up using the two screws (F).
• To screw the plastic support and to close with the plastic mask to mask saw
them.
1
Fig/Abb.1
Fig/Abb 2
E
B
12 mm
4
12 mm
2
4
2
3
3
2
2
1
1
E
C
Fig/Abb 4
4
fixing the keeper
• Fix the keeper using the three screws (E) supplied according to the height
stipulated in the template.
5
electrical connections
• Pass the cables through the correct hole (A) and connect them to C and D
terminals on the PCB.
Important:
This type of lock cannot be used on outward-opening gates.
Leave a space of about 9 millimetres between the keeper and the lock (side
F, figure 4).
During a power cut, the key can always be used so there is never any problem
getting back in.
If you want to test your lock before it is installed, the presence of the keeper
must always be simulated by pressing on the memorisation flap (
activate the mechanical memory.
D
F
F
1