DISPLAY
Indicates the presence of an alarm.
ASPIRATOR
Fumes motor fault
FAULT
FUMES PROBE
Fumes probe failure.
HOT FUMES
High ue gas temperature
The pellet feed-box is empty.
NO
Pellet feed calibration inadequate.
IGNITION
Thermostat bulbs tripped
The pellet feed-box is empty.
NO FLAME
No pellet feed.
The motor reducer does not feed pellets.
The door is not closed correctly.
The ash drawer is not closed correctly.
ALL DEPR
The combustion chamber is dirty.
The ue exhaust pipe is blocked/dirty
The automatic cleaning of the burn pot is
blocked.
TRAPDOOR FAULTY
Burn pot dirty/clogged
The door is not closed correctly.
PRESSURE SENSOR
Di erential pressure sensor faulty, disconnected
FAULTY
or broken.
AUGER CONTROL
Abnormal pellet loading.
AUGER BLOCK
Abnormal operation of pellet motor.
The pellet feed-box is empty.
The door is not closed correctly.
TANK EMPTY
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked.
The automatic cleaning of the burn pot is
blocked.
MAX CURRENT
Burn pot dirty/clogged
The door is not closed correctly.
Pellet tank open.
CLOSE
Door open.
TANK DOOR
Air inlet clogged or dirty.
82

ALARMS

EXPLANATION
ENGLISH
SOLUTION
On: indicates the presence of an alarm.
Flashing: indicates the deactivation of the depression sensor
The alarm can be reset only if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing the key 1/
Contact after-sales centre
Contact after-sales centre
Check pellet feed (see "Easy setup"). If the problem cannot be solved,
contact an authorised technician.
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see "Easy setup").
Check the procedures described in the "Ignition" chapter.
Check the thermostats with bulbs (see chapter on resetting)
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see "Easy setup").
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Check that the door closes correctly. Check that the burn pot is free and
clean The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre
Contact after-sales centre
Contact after-sales centre
Contact after-sales centre
Check for the presence of pellets in the feed-box.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air
channel and the combustion chamber.
Contact after-sales centre
Check that the door closes correctly.
Check that the burn pot is free and clean
The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre
Make sure that the pellet tank, door and ash drawer close properly.
Check air inlet.
for 3 seconds.