Boost mode
In the boost mode, regardless of the set tem-
perature level, the heating element heats con-
tinuously for 60 minutes. The thermostat then
switches back to the comfort mode.
To activate the boost mode or early cancel-
►
lation, press the button (3) briefly.
For safety reasons, the thermostat switches off
on reaching a room temperature of approxi-
mately 28 °C (room temperature regulation
mode) or approximately 35 °C (towel warming
mode).
Display
The LED display mode (4) switches on auto-
matically when the temperature controller is
moved. To increase the life of the batteries,
the display switches off if it is not used for a
prolonged period. Boost mode and battery
change display remain unaffected.
LED display
mode (4)
Blinks red slowly
Blinks yellow slowly
Blinks red quickly
Blinks yellow irregularly
Battery change
The thermostat operates with 2 batteries 1.5 V
of the type LR03 or AAA.
Do not use rechargeable batteries.
Remove the housing cover (5) according to
►
Fig. F1.
Change the batteries. Pay attention to the
►
correct polarity.
Fit the housing cover (5) again.
►
Note: in case of empty batteries, the thermo-
stat no longer sends radio signals to the recei-
ver.
If no radio signal is received for a longer peri-
od, the receiver switches off the heating ele-
ment due to safety reasons. However, the an-
tifreeze function remains active in the receiver
via a temperature sensor.
Meaning
Heating phase
Setpoint tem-
perature has been
reached, heat-
ing element is
switched off
Boost mode is
active
Battery empty -
kindly change
EN – Installation instructions
The device may only be connected by an elec-
trical specialist. An electrical specialist is so-
meone whose technical training, knowledge,
experience and knowledge of the relevant
regulations allows him to assess the tasks assi-
gned to him and recognise potential hazards.
Safety instructions
Read these instructions thoroughly prior to
►
installation and commissioning.
After installation pass the instructions on
►
to the end used.
WARNING
Danger of death from electric shocks!
Install and connect the device only in the
►
de-energized state.
Operating conditions
Install thermostat only in conjunction
►
with electrical heating elements from the
manufacturer's product range.
When installing in rooms with bath or sho-
►
wer facilities: take into account protective
areas according to national installation
standards (in Germany DIN VDE 0100-701).
Also follow all local regulations.
When installing , provide an on-site residu-
►
al-current-operated protective device (with
trigger limit less than or equal to 30 mA).
►
If a device without a connector is directly
connected to the fixed electrical installa-
tions: install an isolator in accordance with
the local provisions for mains disconnec-
tion.
Operate the device only with the approved
►
voltage (see type plate).
Store and transport the device only in the
►
protective packaging.
Complaint
Contact the supplier.
►
Disposal
►
Packaging and any parts that are not nee-
ded should be recycled or disposed of pro-
perly. Observe local regulations.
7