Drukverliezen / Pertes de charge / Druckverluste/ Pressure drop
Jaga Danfoss Deco ventiel RETOUR
Vanne Jaga Danfoss Deco RETOUR
Jaga Danfoss Deco Ventil RÜCHLAUF
Jaga Danfoss Deco valve RETURN
Voorinstelling
Préréglage
Voreinstellung
Pre-setting
Radiatorvoeding %
Alimentation du corps de chauff e %
Vorlauf Heizkörper %
Radiator flow %
Kv: m
3
/h/ΔP=1 bar
0.03 0.06 0.13 0.17 0.23 0.27 0.29 0.34 0.44
Kv (t=2K)
Voorbeeld:
Verwarmingslichaam 0.7 kW
(Tabel ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Voorinstelling = 4
Kv = 0.17 m
3
/u
Exemple:
Échangeur de chaleur 0.7 kW
(Table ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Préréglage = 4
3
Kv = 0.17 m
/h
mWK
mCE
mWS
mWC
bar
10
1
8
0.8
6
0.6
5
0.5
4
0.4
3
0.3
2
0.2
1.5
0.15
1.0
0.1
0.8
0.08
0.6
0.06
0.5
0.05
0.4
0.04
0.3
0.03
0.2
0.02
0.15
0.015
0.1
0.01
0.08
0.008
0.06
0.006
0.05
0.005
0.04
0.004
0.03
0.003
0.02
0.002
0.015
0.0015
0.01
0.001
1
2
3
4 5 6
7
Waterdebiet in kg/u - Débit d'eau en kg/h
Wasserdurchsatz in Kg/St. - Waterflow in kg/h
t= 5°C
0.01
0.02
0.05
t=10°C
0.02
0.05
t=15°C
0.02
0.05
0.1
t=20°C
0.03
0.05
0.1
t=30°C
0.05
0.1
0.2
1
2
3
4
5
6
7
0
100
100
100
100
100
100
Beispiel:
Wärmetauscher 0.7 kW
(Tabelle ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Voreinstellung = 4
Kv = 0.17 m
3
/St.
Example:
Heat exchanger 0.7 kW
(Table ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Pre-setting = 4
3
Kv = 0.17 m
/h
1
2
3
4
5 6 7 KVS
10
20
30 40 50 70 100
200
300 400 500 700
0.1
0.2
0.3 0.4
0.6 0.8
1
2
0.1
0.3 0.4
0.6 0.8
1
2
3
4
0.2
0.3 0.4
0.6 0.8
1
2
3
4
5
0.2
1
2
3
4
5
7
0.2
0.3 0.4
0.6 0.8
2
3
4
5
7
10
0.3 0.4
0.6 0.8
1
Jaga Danfoss Deco ventiel AANVOER
Vanne Jaga Danfoss Deco DÉPART
Jaga Danfoss Deco Ventil VORLAUF
Jaga Danfoss Deco valve FLOW
Aantal omwentelingen
N
NKVS
Anzahl Umdrehungen
Number of rotations
Radiatorvoeding %
Alimentation du corps de chauff e %
100
100
Vorlauf Heizkörper %
Voorbeeld:
Verwarmingslichaam 2 kW
(Tabel ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Voorinstelling = 2
Kv = 0.58 m
3
/u
Exemple:
Échangeur de chaleur 2 kW
(Table ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Préréglage = 2
3
Kv = 0.58 m
/h
mWK
mCE
kPa
mWS
mWC
bar
100
10
1
80
8
0.8
60
50
6
0.6
40
5
0.5
4
0.4
30
3
0.3
20
2
0.2
15
1.5
0.15
10
8
1.0
0.1
0.8
0.08
6
5
0.6
0.06
4
0.5
0.05
0.4
0.04
3
0.3
0.03
2
0.2
0.02
1.5
0.15
0.015
1
0.8
0.1
0.01
0.08
0.008
0.6
0.5
0.06
0.006
0.4
0.05
0.005
0.04
0.004
0.3
0.03
0.003
0.2
0.02
0.002
0.15
0.015
0.0015
0.1
0.01
0.001
1
kW
3
4
5
t= 5°C
kW
5
7
10
t=10°C
kW
7
10
15
t=15°C
0.02
kW
10
20
t=20°C
kW
20
30
t=30°C
Nombre de tours
0.25
0.50
1
0
100
100
Radiator flow %
Kv: m
3
/h/ΔP=1 bar
0.18
0.36
0.47
Kv (t=2K)
Beispiel:
Wärmetauscher 2 kW
(Tabelle ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Voreinstellung = 2
Kv = 0.58 m
Example:
Heat exchanger 2 kW
(Table ∆T =50)
∆T = 10°C (75 - 65 = 10°C)
∆P = 0.1 bar
Pre-setting = 2
Kv = 0.58 m
Aantal omwentelingen om te openen
Nombre de tours à ouvrir
Anzahl Umdrehungen zum Öff nen
Number of rotations to open
2
3
4 5 6
7
10
20
30 40 50 70 100
Waterdebiet in kg/u - Débit d'eau en kg/h
Wasserdurchsatz in Kg/St. - Waterflow in kg/h
0.01
0.02
0.05
0.1
0.2
0.3 0.4
0.02
0.05
0.1
0.3 0.4
0.6 0.8
0.2
0.05
0.1
0.3 0.4
0.6 0.8
0.2
0.03
0.05
0.1
0.3 0.4
0.6 0.8
1
0.2
0.05
0.1
0.2
0.3 0.4
0.6 0.8
1
1.5
2
5
open
100
100
100
100
0.52
0.58
0.58
0.60
3
/St.
3
/h
1 1.5 2 5
0.25
0.5
kPa
100
80
60
50
40
30
20
15
10
8
6
5
4
3
2
1.5
1
0.8
0.6
0.5
0.4
0.3
0.2
0.15
0.1
200
300 400 500 700
kW
0.6 0.8
1
2
3
4
5
kW
1
2
3
4
5
7
10
kW
1
2
3
4
5
7
10
15
kW
2
3
4
5
7
10
20
kW
2
3
4
5
7
10
20
30