PowerPump
6.3
Connecting the pump electrically
CAUTION!
!
Only use cables with the following cable cross section:
2.5 mm² for cable lengths of up to 6 m
4 mm² for cable lengths of more than 6 m
➤ Connect the red positive cable and the black negative cable to the 12 or
24 V power supply.
➤ Install a sufficient fuse in the positive cable, see "Technical data" on
page 19.
7
Using the pump
➤ Open the supply point.
✓ The pump automatically turns on and pumps water.
➤ Close the supply point.
✓ The pump automatically turns off again.
8
Cleaning and caring for the pump
WARNING! Danger of electrocution!
!
Always disconnect the mains plug before you clean and service the
device.
NOTICE! Danger of damaging the device!
A
Never clean the device under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during clean-
ing as these can damage the device.
➤ Occasionally clean the device with a damp cloth.
EN
Using the pump
17