Network Setup of Tx & Rx Extender Units
This setup must be used if you are using 1-to-many or many-to-many configurations.
HDMI Extender TX and RX are setup via web browser. The default IP address of TX is 192.168.168.55
and of RX is 192.168.168.56. An individual IP address must be assigned to each unit, i.e.
IP:192.168.168.XX (XX:1-255), Subnet mask 255.255.255.0, and MAC:00:0b:78:XX:XX-XX (XX:01-FF).
Step 1: Assign the computer's IP address, i.e. 192.168.168.11, through Control Panel, Network
Connections, Local Area Connections, Status, Properties, Internet Protocol (TCP/IP). Press OK to save
the configuration.
Step 2: Turn on the Extender device to be configured. Use an Ethernet Cable to connect the computer
and the device directly.
and disconnect the device.
If you have any problems try to ping the connected device with the new IP address. You will receive the
reply if the connection is established.
Troubleshooting
•
Please only use HDTV/SDTV resolutions like 1080, 720, 576 and 480. Other resolutions may require
to copy the monitor EDID data into the TX.
•
Please check if all power LEDs are lit. Eventually exchange / replace the power supply
•
Please check if all cable connections are seated well
•
Please check if you can ping the extender units
•
If you are not using a separated network, i.e. via VLAN configuration, your network may suffer from
extremely high traffic causing certain network components to fail. If this is the case please contact
an experienced network technician to set up your network. This HDMI Extender is NOT designed to
be used in a network with a wireless broadband router!
•
To do a factory reset press the RESET button for more than 10 seconds
•
If you cannot locate the problem – and if it is NOT just a network problem – please contact LINDY
support team. The worldwide contact information is available from the LINDY website.
Step
3:
Use
a
(TX:192.168.168.55, RX:192.168.168.56). Click the System
menu and setup the required IP address, subnet mask, and
MAC address as mentioned above. It is highly recommended
to label the units with this setting. If you ever forget this
setting you may have to reset the units to factory default
values!
Step 4: Click Apply button. Wait for 10 seconds and turn off
web
browser
to
English
access
the
unit