Please read below warnings and instructions carefully before commencing any
installation.
This mirror cabinet is for indoor use only and light source is non-replaceable.
• The electrical circuit connection should be done by qualified person according to local regulation and law.
• To prevent electrical stock, please switch off the main electrical supply before installing or maintaining the fitting.
• Make sure the cables are not stressed at the wire way.
• Please keep the length of cables exposed with less than 80 mm.
• If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the qualified
person in order to avoid hazard.
(IP44 or higher) Junction box is not included.
It should conform to EN 60998-2-1
o Screw type of junction box: M3 x 4
o Number of terminals: 2 way terminals
o Rated voltage of junction box: 250V/10A
o Rated connecting capactiy suitable for wire with cross-sectional area of 1.5 mm2
Circuit installation Instruction:
The brown cable copper end from the power cord of the mirror cabinet is inserted inde the junction box and screwed on a terminal.
The brown cable copper end from the power cord of wall circuit is also connected and screwed on the same terminal.
The blue cable copper end from the power cord of the mirror cabinet is inserted inde the junction box and screwed on a terminal.
.
The brown cable copper end from the power cord of wall circuit is also connected and screw on the same terminal.
Electrical circuit diagram :
JUCTION BOX WITH IP 44
OR HIGHER (NOT PROVIDED).
Warnings:
BLUE (N)
BROWN (L)