STARTING
1.- Be sure that the pump is correctly primed, then
gently open one tap of the installation.
2.- Conect the COMPACT 2 to electric supply, the
tensionled will lit (POWER).
3.- The pump starts working automatically and
within a period of 20-25 seconds the pressure will
reach aproximately, the maximum pressure
provided by the pump. During its working the
corresponding led (ON) will be on.
4.- Close the tap indicated on point 1. After 10-12
seconds, the pump will stop, The tension led
(POWER) will be the only one to remain on.
Any problem after this procedure will be due to
a defective pump priming.
POSSIBLE PROBLEMS
1.- PUMP DOES NOT STOP:
A) Water leak higher than 1 l/min. at some point:
check that all the used taps are closed.
2.- PUMP DOES NOT START:
A) The pump is not primed; the protection against
dry running operation has stepped in and the
FAILURE led is on: prime the water pipe, drain
the system water by opening tap (A) on the same
level as COMPACT to decrease the pressure of the
water column over it (FIG.2), and check
by pressing the manual start button (RESET).
B) Pump is blocked: led (FAILURE) is on, the
security system is activated. When we act on the
manual start switch (RESET) the led (ON) is
activated but the pump does not work: contact with
your dealer.
C) Failure in the electronic circuit: switch off the
pump from the power supply, wait a few seconds
and turn it on again, the pump should start, if
it does not start then replace the electronic circuit.
D) Not electrical supply: check the proper electric
feeding. The tension led (POWER) should be on.
E) Not enough pump pressure: the security system
has been activated and the corresponding led
(FAILURE) is on. Check that the pump
pressure was at least 1 bar higher than the starting
pressure for the model F,
follow the table in HYDRAULIC CONNECTION.
F) Air in the pump aspiration: Pressure lower
that the nominal or constants oscillations. The
security system will act by stopping the
pump, the LED (FAILURE) will be on. Check
the sealing of the connections and the O-ring of
the aspiration conduct.
3.- PUMP STARTS AND STOPS REPEATEDLY:
Small leak in some point of the installation: Verify
possible taps or WC tank leaks and repair them.
and for the model R
INSTALLATION OF THE PRESSURE
GAUGE (FIG. 1) (OPTIONAL)
The pressure gauge has an O-ring and two fixing
screws. The pressure gauge must be mounted in
the side with the three holes, one big central
hole and two more little for fixing the gauge by
means of the two supplied screws. Previously you
should remove the screw located in the central hole
and then introduce the cylindrical connector of the
pressure gauge. Then fix the pressure gauge
with the two screws supplied with it.FIG. 4.
SERVICE DEPARTMENT
_ Damaged switches must be replaced by our after-
sales service department.
_ If replacing the power cord is necessary, it
should be done by the manufacturer or his agent
to avoid a hazard.
AFTER-SALES SERVICE AND
APPLICATION SERVICE
Our after-sales service responds to your questions
concerning maintenance and repair of your product
as well as spare parts. Exploded views and
information on spare parts can also be found
under:www.eco-repa.com
ELEM PROFESSIONAL WATER PUMPS
application service team will gladly answer
questions concerning our products and their
accessories : sav@eco-repa.com
STORAGE
_ Thoroughly clean the whole machine and its
accessories.
_ Store it out of the reach of children, in a stable and
secure position, in a cool and dry place, avoid too
high and too low temperatures.
_ Protect it from exposure to direct sunlight. Keep it
in the dark, if possible.
_ Don't keep it in plastic bags to avoid humidity
build-up.
GUARANTEE
Refer to the enclosed guarantee conditions for the
terms and conditions of guarantee.
ENVIRONMENT
Should your machine need
extended use, do not put it in the
domestic waste but dispose of it
in an environmentally safe way.
Made in spain
replacement after
2019