Air Filter Removal - Danby DDR2611 Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
AIR FILTER
Fig. 2
DIRECT DRAIN
FEATURE
Fig. 3
Fig.4a
Your dehumidifer features a removable Air Filter, located at the front of
the unit (behind the air intake grill) directly above the water tank
compartment.
The air filter plays an important role in helping to reduce (minimize)
dust/dirt particles from the surrounding environment. A blocked/clogged air
filter reduces air intake, impacting negatively on operating efficiency.
To maintain maximum operating efficiency:
• The filter must be checked and cleaned regularly (every 2 weeks)
• More frequent cleaning may be required depending upon indoor air
quality.
IMPORTANT: Never operate the unit without the air filter in place.

AIR FILTER REMOVAL:

1) Grasp the filter handle, and pull the filter out. The filter will slide out
easily (see Fig. 2)
2) Clean the filter thoroughly using a vacuum cleaner or wash using
lukewarm water and mild detergent. Dry thoroughly before re-installing.
3) To re-install the air filter, slide the filter back inside the tracks and push
inward.
This dehumidifier is inclusive of a direct drain feature, located at the right side
of the cabinet. NOTE: The drain hose is not included with the unit. The
direct drain feature is intended for use in basements inclusive of a floor
drain only.
NOTE: Do not attempt to operate the direct drain feature using
Water can be automatically emptied into a floor drain by attaching the unit
with a water hose (24mm diameter not included)
• Remove the water bucket from the unit and set aside.
• Lift up the side flap located on the right side of the unit (looking at the
front). (Fig.3)
• Insert the female threaded end of the hose through the opening. (Fig.4a)
• Screw the garden hose onto the threaded portion of the tray underneath
the bucket opening. (Fig.4b)
• Make sure the hose is secure so there are no leaks.
• Direct the hose toward the drain, making sure that there are no kinks
that will stop the water flowing.
• Place the end of the hose ino the drain.
• Place the bucket back in the unit and make sure its positioned correctly.
(Fig.4c)
• Select the desired humidity setting and fan speed on the unit for
continuous draining to start.
Fig.4b
8
Fig.4c

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ddr4011

Table des Matières