Publicité

Liens rapides

LS25-150 Installation Manual
ENGLISH
General Safety Instructions:
READ SAFETY INSTRUCTIONS
Servicing:
These products are not customer serviceable TDK-Lambda and their authorised agents only are permitted to carry out repairs.
Critical Components:
These products are not authorised for use as critical components in nuclear control systems, life support systems or equipment for use in
hazardous environments without the express written approval of the Managing Director of TDK-Lambda EMEA.
Product Usage:
These products are designed for use within a host equipment which restricts access to authorised competent personnel.
This product is a component power supply and complies with the EMC directive. The EMC performance of a component power supply will be
affected by the final installation, compliance to the stated EMC standards and conformance to the EMC Directive must be confirmed after
installation by the final equipment manufacturer.
For guidance with respect to test conditions please visit our website at https://emea.tdk-lambda.com/EMC_guidance or contact your local TDK-
Lambda sales office.
Environmental:
These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids must not be used.
Environment:
This power supply is a switch mode power supply for use in applications within a Pollution Degree 2, overvoltage category II environment. Material
Group IIIb PCB's are used within it.
Output Loading:
The output power taken from the power supply must not exceed the rating stated on the power supply label, except as stated in the product
limitations in this handbook.
Input Parameters:
This product must be operated within the input parameters stated in the product limitations in this handbook.
End of Life Disposal:
The unit contains components that require special disposal. Make sure that the unit is properly disposed of at the end of its service life and in
accordance with local regulations.
RISK OF ELECTRIC SHOCK
High Voltage Warning:
Dangerous voltages are present within the power supply. The professional installer must protect service personnel from inadvertent contact with
these dangerous voltages in the end equipment.
WARNING: When installed in a Class 1 end equipment, this product must be reliably earthed and professionally installed.
The (+) or (-) output(s) can be earthed or left floating.
The unit cover(s)/chassis (where applicable) must not be made user accessible.
The mains input connector is not acceptable for use as field wiring terminals.
For encased products, do not use mounting screws, which penetrate the unit more than; See drawings.
Internal fuses protect the unit and must not be replaced by the user. In case of internal defect, the unit must be returned to TDK-Lambda or one of
their authorised agents.
A suitable mechanical, electrical and fire enclosure must be provided by the end use equipment for mechanical, electric shock and fire hazard
protection.
Energy Hazards:
The main output of this product is capable of providing hazardous energy (240VA). Final equipment manufacturers must provide protection to
service personnel against inadvertent contact with the output terminals.
The unit cover/chassis, where applicable, is designed to protect skilled personnel from hazards. They must not be used as part of the external
covers of any equipment where they may be accessible to operators, since under full load conditions, part or parts of the unit chassis may reach
temperatures in excess of those considered safe for operator access.
Page 1 of 6
24 November 2017
PA582-04-01-F (b)

Publicité

Table des Matières
loading

Sommaire des Matières pour TDK-Lambda LS25-150

  • Page 1 For encased products, do not use mounting screws, which penetrate the unit more than; See drawings. Internal fuses protect the unit and must not be replaced by the user. In case of internal defect, the unit must be returned to TDK-Lambda or one of their authorised agents.
  • Page 2: Allgemeine Sicherheitsvorschriften

    Allgemeine Sicherheitsvorschriften: LESEN SIE DIE SICHERHEITSVORSCHRIFTEN Wartung: Diese Produkte können nicht durch den Kunden gewartet werden. Nur TDK-Lambda und deren zugelassene Vertriebshändler sind zur Durchführung von Reparaturen berechtigt. Kritische Komponenten: Diese Produkte sind nicht für die Verwendung als kritische Komponenten in nuklearen Kontrollsystemen, Lebenserhaltungssystemen oder Geräten in gefährlichen Umgebungen geeignet, sofern dies nicht ausdrücklich und in Schriftform durch den Geschäftsführer von TDK-Lambda...
  • Page 3: Consignes Générales De Sécurité

    LIRE LES CONSIGNES DE SECURITE Entretien: Ces produits ne peuvent pas être réparés par l’utilisateur. Seuls, TDK-Lambda et ses agents agréés sont autorisés à effectuer des réparations. Composants critiques: Ces produits ne doivent pas être utilisés en tant que composants critiques dans des systèmes de commande nucléaire, dans des systèmes de sauvetage ou dans des équipem ents utilisés dans des environnements dangereux, sans l'autorisation écrite expresse du directeur général de...
  • Page 4: Norme Generali Di Sicurezza

    Norme generali di sicurezza: SI PREGA DI LEGGERE LE NORME DI SICUREZZA Manutenzione: Il cliente non può eseguire alcuna manutenzione su questi prodotti. L'esecuzione delle eventuali riparazioni è consentita solo a TDK-Lambda e ai suoi agenti autorizzati. Componenti critici: Non si autorizza l'uso di questi prodotti come componenti critici all'interno di sistemi di controllo nucleari, sistemi necessari alla sopravvivenza o apparecchiature destinate all'impiego in ambienti pericolosi, senza l'esplicita approvazione scritta dell'Amministratore Delegato di TDK-Lambda EMEA.
  • Page 5: Instrucciones Generales De Seguridad

    Instrucciones generales de seguridad: LEA LAS INSTRUCCIONES DE SEGURIDAD Servicio: Estos productos no pueden ser reparados por los clientes. TDK-Lambda y sus agentes autorizados son los únicos que pueden llevar a cabo las reparaciones. Componentes fundamentales: Estos productos no pueden ser utilizados como componentes fundamentales en sistemas de control nuclear, sistemas de soporte vital o equipos a utilizar en entornos peligrosos sin el consentimiento expreso por escrito del Director General de TDK-Lambda EMEA.
  • Page 6: Instruções Gerais De Segurança

    Instruções gerais de segurança: LEIA AS INSTRUÇÕES DE SEGURANÇA Manutenção: Estes produtos não são podem ser submetidos a manutenção por parte do cliente. Apenas a TDK-Lambda e os seus agentes autorizados têm permissão para realizar reparações. Componentes essenciais: Não é autorizada a utilização destes produtos como componentes essenciais de sistemas de controlo nuclear, sistemas de suporte de vida ou equipamento para utilização em ambientes perigosos sem a expressa autorização por escrito do Director-Geral da TDK-Lambda EMEA.
  • Page 7: Warning And Caution

    TDK-Lambda Series 25-150 INSTRUCTION MANUAL BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. WARNING and CAUTION ...
  • Page 8 TDK-Lambda Series 25-150 INSTRUCTION MANUAL 1. Terminal Explanation LS25, LS35, LS50, LS75 (1) L : Input terminal Live line (Fuse in line) (2) N : Input terminal Neutral line (3) FG : Functional Ground (4) - V : - Output terminal...
  • Page 9 TDK-Lambda Series 25-150 INSTRUCTION MANUAL 3. Explanation of Functions and Precautions 3-1. Input Voltage Range Input voltage range is single phase 88 ~ 264VAC (47 ~ 63Hz) or 125 ~ 373VDC for LS25 ~ LS100. For LS150, selectable switch 115/230VAC will decide the input voltage range as mentioned in the table below.
  • Page 10: Parallel Operation

    TDK-Lambda Series 25-150 INSTRUCTION MANUAL Method ( A ) Method ( B ) Power Power Supply Supply Output Load Terminal Output Terminal Load Output Output Load Terminal Terminal Note : In case of Method ( A ), please connect diodes to prevent the reverse voltage.
  • Page 11 TDK-Lambda Series 25-150 INSTRUCTION MANUAL of DC isolation tester must be done before the test. Ensure that the unit is fully discharged after the test. (a) Output ~ FG (chassis) : 500VDC, 100M or more AC(L) AC(N) Isolation Tester 4-2. Withstand Voltage This series is designed to withstand 3.0kVAC between input and output, 1.5kVAC between input and FG (chassis) and...
  • Page 12 TDK-Lambda Series 25-150 INSTRUCTION MANUAL trapped inside the unit. In the following derating curve, the maximum output current is denoted as 100%. (A) Output Derating versus Ambient Temperature (Convection Cooling) LS25-3.3 Output Derating Vs Ambient Temperature Load (%) Mounting A & D Mounting B &...
  • Page 13 TDK-Lambda Series 25-150 INSTRUCTION MANUAL Output Derating Vs Ambient Temperature Load (%) Mounting A & D Mounting B & C 65 70 Ambient Temperature ( LS35-3.3, -5, -12, -15, -24, -36 & -48 Output Derating Vs Ambient Temperature Load (%) Mounting A,B &...
  • Page 14 TDK-Lambda Series 25-150 INSTRUCTION MANUAL Load (%) Output Derating Vs Ambient Temperature Mounting A, B & D Mounting Ambient Temperature (°C) LS75-3.3, -5 Load (%) Output Derating Vs Ambient Temperature Mounting A, B & D Mounting Ambient Temperature (°C) LS75-12, -15, -24, -36 & -48...
  • Page 15 TDK-Lambda Series 25-150 INSTRUCTION MANUAL Load (%) Output Derating Vs Ambient Temperature Mounting A, B & D Mounting Ambient Temperature (°C) LS100-3.3, -5 Output Derating Vs Ambient Temperature Load (%) Mounting A & B Mounting C & D Ambient Temperature (°C)
  • Page 16 TDK-Lambda Series 25-150 INSTRUCTION MANUAL Output Derating Vs Ambient Temperature Load (%) Mounting A & B Mounting C & D Ambient Temperature (°C) LS150-3.3, -5 Load (%) Output Derating Vs Ambient Temperature Mounting Mounting B, C & D Ambient Temperature (°C)
  • Page 17 TDK-Lambda Series 25-150 INSTRUCTION MANUAL Load (%) Output Derating Vs Ambient Temperature Mounting Mounting B, C & D Ambient Temperature (°C) (B) Output Derating versus Input Voltage (Convection Cooling) LS100-3.3, -5, -12, -15, -24, -36 & -48 Output Derating Vs Input Voltage...
  • Page 18: Wiring Method

    TDK-Lambda Series 25-150 INSTRUCTION MANUAL tance of more than 15mm between the power supply and the peripheral parts. When lining up multiple units, please make sure to place them 15mm or more apart from each other. Maximum allowable penetration of mounting screws into the power-supply is 5mm except LS25 (4mm).
  • Page 19: Warranty Condition

    This product is under warranty for 3 years (based on 8 hours/day operation) from the date of shipment. During the warranty period, TDK-Lambda will, at it’s option, either repair or replace products prove to be defective. Warranty applies but not limited to the following.

Table des Matières