Télécharger Imprimer la page

Publicité

Liens rapides

User Manual
GB
Manuel d'utilisation
F
Manual de usuario
E
Gebrauchsanleitung
D
Manuale dell'utente
I
www.poollab.org
V9

Publicité

loading

Sommaire des Matières pour PoolLab 1.0

  • Page 1 User Manual Manuel d’utilisation Manual de usuario Gebrauchsanleitung Manuale dell’utente www.poollab.org...
  • Page 2 CONTENT Delivery content Changing Batteries Switch on/off General Advices 6 - 7 ZERO 8 - 9 TEST - pH 10 - 11 TEST - Cl - Chlorine 12 - 15 TEST - CYA - Cyanuric Acid 16 - 17 TEST - TA - Alkalinity 18 - 19 TEST - Active Oxygen (MPS) 20 - 21...
  • Page 3 Delivery content • Contenu du colis • Contenido de la entrega • Lieferumfang • contenuto della confezione PoolLab 1.0 Light shield AAA Batteries Crushing / Stirring Rods 10ml syringe User guide 20 x Phenol Red Photometer tablets 20 x DPD N° 1 Photometer tablets 10 x DPD N°...
  • Page 4 Batteries • Piles • Pilas • Batterien • Batterie Change • chargement • cambio • wechseln • cambiamento 3 x AAA...
  • Page 5 Switch on • Allumer • Encender • Einschalten • Accendere 2 sec. · ZERO On/Off button can also be used to skip countdown during measurement (not recommended) Le bouton Marche / Arrêt peut être également utilisé pour ignorer le compte à rebours lors de la mesure (non recommandé) El botón de On/Off también se puede utilizar para cancelar la cuenta atrás durante la medición (no se recomienda) Der On/Off Knopf kann auch zum Abbrechen des Countdowns...
  • Page 6 Advices • Conseils • Consejos • Hinweise • Consigli Always use PHOTOMETER grade tablets! Never use RAPID grade tablets! Do not touch reagent tablets! Toujours utiliser des pastilles de qualité PHOTOMETRE! Ne jamais utiliser des pastilles de qualité "RAPID" ! PHOTOMETER Ne touchez pas les pastilles avec les mains!
  • Page 7 IMPORTANT • IMPORTANTE • WICHTIG Detergent waterproof (IP68 ) ZERO It is important to clean the device after each measurement to get rid of any reagent residues! Il est important de nettoyer le dispositif après chaque mesure pour éliminer les résidus de réactifs! Es importante limpiar el dispositivo después de cada medición para deshacerse de cualquier residuo de reactivo!
  • Page 8 ZERO 3 x = waterproof (IP68 ) ZERO take 10 ml water sample waterproof (IP68 ) 10 ml ZERO ZERO ZERO...
  • Page 9 Only 1 time per test batch • Une seule fois par lot de test • Sólo una vez por lote de prueba • Nur 1 x pro Testreihe • solo una volta per test in batch Once you performed ZERO, all measurements, like pH, chlorine... can be done one after each other without the need to do a ZERO again.
  • Page 10 Range: 6.50 - 8.40 pH Reagent: Phenol Red Photometer 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 11 After / Après / Después de / Nach / Dopo ZERO completely Phenol Red dissolved Photometer residue ZERO ZERO 15 sec. · ZERO ZERO...
  • Page 12: Chlorine Chlore Cloro Chlor Cloro

    Chlorine Chlore Cloro Chlor Cloro Range: 0.00 - 6.00 mg/l (ppm) Reagents: DPD N° 1 Photometer DPD N° 3 Photometer 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 13 After / Après / Después de / Nach / Dopo ZERO Free Chlorine • Chlore libre • Cloro libre • Freies Chlor • Cloro libero N° 1 Photometer completely dissolved ZERO ZERO residue Total Chlorine 15 sec. · ZERO ZERO...
  • Page 14 Total Chlorine • Chlore total • Cloro total • Gesamt-Chlor • Cloro totale N° 3 Photometer ZERO ZERO completely dissolved · ZERO ZERO pH ZERO TA residue...
  • Page 15 Total Chlorine is measured directly after free Chlorine without emptying the cuvette. The DPD 3 tablet is added to the sample water which already contains the DPD 1 tablet (dissolved). Combined Chlorine is calculated as Total Chlorine minus free Chlorine. Le chlore total est mesuré...
  • Page 16 Cyanuric Acid Acide cyanurique Ácido cianúrico Cyanursäure Acido Cianurico Range: 0 - 160 mg/l (ppm) Reagent: CYA-Test Photometer 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 17 After / Après / Después de / Nach / Dopo ZERO Cyan. Acid • Acide Cyan • Ácido Cian. • Cyanursäure • Acido Cianurico CYA-Test completely Photometer dissolved ZERO ZERO residue 15 sec. · ZERO ZERO...
  • Page 18 Alkalinity Alcalinité Alcalinidad Alkalinität Alcalinità Range: 0 - 300 mg/l (ppm) CaCO Reagent: Alkalinity-M Photometer 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 19 After / Après / Después de / Nach / Dopo ZERO Alkalinity • Alcalinité • Alcalinidad • Alkalinität • Alcalinità Alkalinity-M Photometer completely dissolved ZERO ZERO residue 25 sec. · ZERO ZERO...
  • Page 20 Active Oxygen (MPS) Oxygène actif (MPS) Oxígeno activo (MPS) Aktivsauerstoff (MPS) Ossigeno Attivo (MPS) Range: 0.0 - 30.0 mg/l (ppm) Reagent: DPD N° 4 Photometer* *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 21 After / Après / Después de / Nach / Dopo ZERO Active Oxygen • Oxygène actif • Oxígeno activo Aktivsauerstoff • Ossigeno Attivo N° 4 Photometer* completely dissolved ZERO ZERO residue 120 sec. · ZERO ZERO...
  • Page 22 Chlorine Dioxide Dioxyde de Chlore Dióxido de cloro Chlordioxid Biossido di Cloro Range: 0.0 - 11.4 mg/l (ppm) Reagent: DPD N° 1 Photometer Glycine* *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 23 After / Après / Después de / Nach / Dopo ZERO Cl.Dioxide • Dioxyde de Cl • Dióxido de Cl Chlordioxid • Biossido di Cl Only if your water sample does contain Chlorine next to Chlorine Dioxide (both disinfectants used), the following procedure "A" needs to be followed and Glycine reagent needs to be used.
  • Page 24 After / Après / Después de / Nach / Dopo ZERO Cl.Dioxide • Dioxyde de Cl • Dióxido de Cl Chlordioxid • Biossido di Cl With Chlorine / Avec du Chlore / Con Cloro / Mit Chlor / Con il Cloro Glycine* completely dissolved...
  • Page 25 After / Après / Después de / Nach / Dopo ZERO Cl.Dioxide • Dioxyde de Cl • Dióxido de Cl Chlordioxid • Biossido di Cl Without Chlorine / Sans Chlore / Sin Cloro / Ohne Chlor / Senza Cloro DPD N° 1 Photometer completely dissolved...
  • Page 26 Bromine Brome Bromo Brom Bromo Range: 0.0 - 13.5 mg/l (ppm) Reagent: DPD N° 1 Photometer Glycine* *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 27 After / Après / Después de / Nach / Dopo ZERO Bromine • Brome • Bromo • Brom • Bromo Only if your water sample does contain Chlorine next to Bromine (both disinfectants used), the following procedure "A" needs to be followed and Glycine reagent needs to be used.
  • Page 28 After / Après / Después de / Nach / Dopo ZERO Bromine • Brome • Bromo • Brom • Bromo With Chlorine / Avec du Chlore / Con Cloro / Mit Chlor / Con il Cloro Glycine* completely dissolved ZERO ZERO residue DPD N°...
  • Page 29 After / Après / Después de / Nach / Dopo ZERO Bromine • Brome • Bromo • Brom • Bromo Without Chlorine / Sans Chlore / Sin Cloro / Ohne Chlor / Senza Cloro DPD N° 1 Photometer completely dissolved ZERO ZERO residue...
  • Page 30 Ozone Ozono Ozon Range: 0.00 - 4.00 mg/l (ppm) Reagent: DPD N° 1 Photometer DPD N° 3 Photometer Glycine* *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 31 After / Après / Después de / Nach / Dopo ZERO Ozone • Ozono • Ozon Only if your water sample does contain Ozone next to Chlorine (both disinfectants used), the following procedure "B" needs to be followed and Glycine reagent needs to be used. Otherwise (only Ozone present), please follow procedure "A".
  • Page 32 After / Après / Después de / Nach / Dopo ZERO Ozone • Ozono • Ozon Without Chlorine / Sans Chlore / Sin Cloro / Ohne Chlor / Senza Cloro DPD N° DPD N° (Photometer) completely dissolved ZERO ZERO residue 120 sec.
  • Page 33 After / Après / Después de / Nach / Dopo ZERO Ozone • Ozono • Ozon With Chlorine / Avec du Chlore / Con Cloro / Mit Chlor / Con il Cloro DPD N° DPD N° (Photometer) completely dissolved ZERO ZERO residue 120 sec.
  • Page 34 After / Après / Después de / Nach / Dopo ZERO Ozone • Ozono • Ozon With Chlorine / Avec du Chlore / Con Cloro / Mit Chlor / Con il Cloro 0 ml 0 ml ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 35 After / Après / Después de / Nach / Dopo ZERO Ozone • Ozono • Ozon With Chlorine / Avec du Chlore / Con Cloro / Mit Chlor / Con il Cloro DPD N° DPD N° (Photometer) completely dissolved ZERO ZERO residue 120 sec.
  • Page 36 Hydrogen Peroxide Peroxyde d'Hydrogène Peróxido de Hidrógeno Wasserstoffperoxid Perossido di Idrogeno (LR) Range: 0.00 - 2.90 mg/l (ppm) Reagent: Hyd. Peroxide LR Photometer* *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 37 After / Après / Después de / Nach / Dopo ZERO Hyd. Perox. • Perox. d‘hyd. • Peróx. de Hidr. Wasserstoffperox. • Peross. di Idrog. Hyd. Peroxide LR Photometer* completely dissolved ZERO ZERO residue 120 sec. · ZERO ZERO...
  • Page 38 Hydrogen Peroxide Peroxyde d'Hydrogène Peróxido de Hidrógeno Wasserstoffperoxid Perossido di Idrogeno (HR) Range: 0 - 200 mg/l (ppm) Reagent: Hyd. Peroxide HR Phot.* Acidifying PT *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 39 After / Après / Después de / Nach / Dopo ZERO Hyd. Perox. • Perox. d‘hyd. • Peróx. de Hidr. Wasserstoffperox. • Peross. di Idrog. Acidifying completely dissolved ZERO ZERO residue Hyd. Peroxide Photometer* completely dissolved ZERO ZERO residue 15 sec. ·...
  • Page 40 Total Hardness Dureté Totale Dureza Total Gesamthärte Durezza Totale Range: 0 - 500 mg/l (ppm) Reagent: POL20TH1 /POL10TH2 *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 41 After / Après / Después de / Nach / Dopo ZERO Total Hardn. • Dureté Totale • Dureza Total Gesamthärte • Durezza Totale POL20TH1* POL10TH2* 10 x ZERO ZERO 120 sec. · ZERO ZERO...
  • Page 42 Calcium Hardness Dureté Calcique Dureza de Calcio Kalziumhärte Durezza del Calcio Range: 0 - 500 mg/l (ppm) Reagent: POL20CaH1 /POL20CaH2 *not part of standard equipment 3 x = waterproof (IP68 ) ZERO 10 ml waterproof (IP68 ) 10 ml ZERO...
  • Page 43 After / Après / Después de / Nach / Dopo ZERO Calcium Hard. • Dureté Calcique • Dureza de Calcio • Kalziumhärte • Durezza del Calcio POL20CaH1* POL20CaH2* 10 x 10 x ZERO ZERO 30 sec. · ZERO ZERO...
  • Page 44 OR-UR / Dilution • OR-UR / Verdünnung • OR-UR / Dilución • OR-UR / Diluzione OR = Overrange / UR = underrange. Test result is outside the range of the method. OR results can be brought into measurement range by dilution. Use syringe to take only 5ml (or 1ml) sample water plus 5ml (9ml) distilled water.
  • Page 45 Error codes • Codes d'erreur • Códigos de error • Fehlercodes • codici di errore BAT!: Change batteries • Changer les piles • Cambiar las pilas • Batterien wechseln • Cambiare le batterie Err02: (too dark) Clean measurement chamber or dilute sample •...
  • Page 46 Changing the cuvette • Changer la cuvette Cambiar la cubeta • Küvettenwechsel cambiando la cuvetta 90° ZERO ZERO 90° click ZERO ZERO...
  • Page 47 20ml POLCaH1 (50 tests) POL20CaH2 20ml POLCaH2 (50 tests) Spare parts • Pièces de rechange • Piezas de repuesto • Ersatzteile • Pezzi di ricambio POLsp-kv Replacement cuvette POLsp-str Plastic stirring/crushing rod POLsp-ls Rubber light shield POLsp-box PoolLab carrying box POLsp-RSK-f Reference standard-kit...
  • Page 48 Software / App • Logiciels / App • Software / Aplicación • Software / App • Software / App Bluetooth ON Bluetooth OFF ZERO Windows/ MacOS: www.poollab.org...
  • Page 49 Technical data • Données techniques • Datos técnicos • Technische Daten • Dati tecnici TEST: Cl 0.00 - 6.00 ± 10 % mg/l 6.50 - 8.40 ± 0.1 pH - 160 ± 15 % mg/l - 300 ± 15 % mg/l CaCO Act.Ox...
  • Page 50 The manufacturer of this device, Water-i.d. GmbH, Daimlerstr. 20, D-76344 Eggenstein will dispose of your PoolLab Photometer free of charge (not including costs of sending the device to us). Send your PoolLab for disposal -freight prepaid- to the address shown above.
  • Page 51 CE compliance statement We, the manufacturer of the PoolLab 1.0 Photometer hereby declare comliance of PoolLab 1.0 Photometer with the essential requirements in accordance to the Directive 2014/53/UE of the European Parliament and of the Council of April 16th, 2014: ETSI EN 300 328 (V2.1.1)
  • Page 52 FCC Part 15 compliance statement IC licence-exempt RSS compliance statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 53 Cet émetteur ne doit pas être co-situé ou fonctionner conjointement avec une autre antenne ou un autre émetteur. Changes or modifications not expressly approved by Water-i.d. GmbH could void the user‘s authority to operate the equipment. FCC ID: 2ALRR-POOLLAB10 22610- POOLLAB10 Model: POOL LAB 1.0...
  • Page 54 NOTES • NOTAS • NOTIZEN • NOTE...
  • Page 55 NOTES • NOTAS • NOTIZEN • NOTE...
  • Page 56: Certificate Of Compliance

    Certificate • Certificat • Certificado • Zertifikat • Certificato CERTIFICATE OF COMPLIANCE We hereby certify that the device PoolLab 1.0 With it‘s serial number as stated below, has passed intensive visual and technical checks as part of our QM documentation.