Télécharger Imprimer la page

CDVI ADC123A Manuel D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
ADC123A
switching power supply
PRODUCT PRESENTATION
Regulated supply.
Primary protected by 250V/2A fuse
and secondary protected by automatic fuse.
Possibility of connecting two battery 12 V.**
Input voltage: 230 to 240V, 50/60Hz.
Consumption: 0.25A.
PWM regulation (pulse with modulation).
Cutting frequency: 80 kHz.
Output: regulated 12V dc.
- Off-load: 13.75V.
- On-load: 13.50V/3A.
- Total output power: 36W max.
Maximum current: 3A.
Mains protection by internal fuse: 2A.
Display: Green LED indicates presence
of principal output voltage.
Wall fi xing (screw and plastic anchor included)*
** Fit a fuse in series with the batteries.
Output protected by resettable fuse. (After an
overload or short-circuit, disconnect the network
for 1 minute to reset the fuse.)
TERMINAL
BLOCK OUTPUTS
4 - 5
6 - 7
8 - 9
10
N
L
COMPLIANT WITH EUROPEAN STANDARDS
EN 55022
EN 61000-4-2
EN 61000-3-2
EN 61000-4-3
EN 61000-3-3
EN 61000-4-4
This product must be installed in accordance
with the local safety standards.
2
cdvigroup.com
VOLTAGE
0V dc
+12V dc
- BAT
+ BAT
230V ac
230V ac
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
* Wall fi xing
on each side
60
92
WEEE & RoHS
IP20
WARNING:
Switch off the power before opening
ADC12
Après une surcharge ou un c.c
pour réarmer le fusible débrancher
PRIMARY / PRIMAIRE
le réseau pendant 1mn
After a power overload or a short
230 V
50Hz ; 0,25 A
circuit, cut the power during 1
minute to reset the fuse
SECONDARY / SECONDAIRE
12 V
3 A
36 VA
N
L
LED: Presence of output voltage
Mains terminal block cover in the event of mounting
outside a standard electrical equipment box.
EN
142
CE certifi cation
-25°C to +55°C
4 5 6 7 8 9 10

Publicité