- EN -
Cleaning the quartz glass / Replacing the UVC lamp
Replace the UVC lamp after max. 8,000 operating hours. This ensures optimum filtering performance.
C A U T I O N
Quartz glass and UVC lamp can break and cause cut injuries.
• Handle the quartz glass and UVC lamp with care.
Prerequisite
• The unit head is removed. (→ Dismantling the unit head)
• Ensure that the identification and capacity data of the UVC lamps used correspond to the information on the unit type
plate. (→ Technical data)
How to proceed:
G
1. Loosen the self-tapping screw until the the screw tip is sunk in the housing of the clamping screw.
2. Unscrew the clamping screw counter-clockwise.
3. Remove the quartz glass including the O ring towards the front with a slight turning movement.
4. Pull out the UVC lamp and replace.
5. Push the quartz glass including the O ring as far as the stop in the unit head.
– Clean the O ring, replace if damaged.
– Ensure that the O ring is located in the gap between the unit head and the quartz glass.
6. Tighten the clamping screw clockwise up to the stop.
7. Tighten the self-tapping screw.
8. Wipe the quartz glass tube with a damp cloth
9. On completion of the work, fit the unit head. (→ Fitting the unit head)
Wear parts
• UVC lamp, quartz glass and O ring for quartz glass
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Technical data
Description
Rated voltage
Mains frequency
Power consumption
Protection type
Permissible water temperature
UVC lamp
Type
Recommended max. flow rate
Operating pressure
Max.
Dimensions
Length
Width
Height
Weight
14
V AC
Hz
W
°C
l/h
bar
mm
mm
mm
kg
Clarifier 9W
230
50
12
IP24
+4 ... +35
9 W TC-S (UV-C)
≤ 1700
0.5
330
120
100
1.4