Télécharger Imprimer la page

SUCO 0645 Série Mode D'emploi page 2

Publicité

Connexions électriques
DIN EN 175301-803-A
M 12–DIN EN
61076-2-101-A
2
2
PE
3
1
3
0645 + 0650
0660
0645 + 0650
0660
0675 + 0680
0690
0675 + 0680
0690
1: U
1: U
1: U
1: U
v+
v+
v+
v+
2: Gnd
2: I
2: U
2: nc
Out
Out
3: U
3: nc
3: Gnd
3: I
Out
Out
PE
4: nc
4: nc
IP65
IP67
h ~ 60 mm
(sans connecteur)
h ~ 54 mm
h ~ 76 mm
(avec connecteur)
d ~ Ø 30 mm
d ~ Ø 22 mm
Code: 013
Code: 002
Câble
1: rouge
2: blanc
3: noir
Code de fi letage:
41
0645 + 0650
0660
0675 + 0680
0690
1: U
1: U
v+
v+
2: U
2: nc
Out
3: Gnd
3: I
Out
IP67
h ~ 44 mm (+ 20 mm la
protection anti-courbure);
Longueur de câble ~ 2 m
d ~ Ø 22 mm
Code: 011
1
(1) Connexion électrique
d
(2) Raccord Hydraulique / pneumatique
h
(h) Hauteur
hex 22
2
Montage
Mécanique, hydraulique, pneumatique:
Visser le transmetteur de pression sur le
raccordement de pression à l'aide d'une clé
plate de 22 (suivant DIN 894ou similaire).
Pour assurer l'étanchéité du montage, utiliser
un joint approprié au fi letage retenu. Pour les
fi letages avec joint intégré, aucun système
d'étanchéité supplémentaire n'est nécessaire.
Raccordement électrique:
Vérifi er que le positionnement de joint de connecteurs est correctement
positionné, et que le presse-étoupe Pg (pour DIN EN 175301-A) est
parfaitement mis en place, sans quoi l'indice de protection IP65 ne pourra
être assuré.
Attacher une attention particulière lors du câblage du connecteur DIN EN
175301-A:
– respecter le schéma de connexion
– vérifi er l'absence d'écrasement sur le chemin de câble
– presse-étoupe Pg vissé avec un couple de 20 cNm
Démontage
Lors du démontage du transmetteur de pression, veuillez respecter les
points suivants:
• Avant de démonter le transmetteur de pression, éliminer toute pression
dans le circuit.
• Respecter toutes les règles de sécurité applicables en vigueur.
• Respecter toutes les règles de sécurité applicables en vigueur.
Dévisser le transmetteur de pression du raccordement de pression à l'aide
d'une clé plate de 22 (suivant DIN 894ou similaire).
Marquage CE
Les
transmetteurs
de
pression SUCO tombent sous
la Directive CEM 2014/30/
EU.
Les
déclarations
de
conformité CE ont été établies
pour les transmetteurs de
pression et sont disponibles
sur
simple
demande,
ou
téléchargeables directement
sur
notre
site
internet.
Les
appareils
portent
le
marquage CE.
Explication des symboles:
Attention
Nota,
Recyclable
remarque
Nos produits étant continuellement en développement, nous nous
réservons le droit d'apporter toutes modifi cations sans préavis.
Electrical connections
ISO 15170-A1-4.1
DIN EN 175301-803-A
1
1
4
PE
4
3
2
0645 + 0650
0660
0645 + 0650
0675 + 0680
0690
0675 + 0680
1: U
1: U
1: U
v+
v+
v+
2: Gnd
2: nc
2: Gnd
3: U
3: I
3: U
Out
Out
Out
4: nc
4: nc
PE
IP67
IP65
h ~ 60 mm
(without connector)
h ~ 65 mm
h ~ 76 mm
(with connector)
d ~ Ø 27 mm
d ~ Ø 30 mm
Code: 004
Ordernumber: 013
Cabel connection
0645 + 0650
0675 + 0680
1: U
v+
2: U
Out
3: Gnd
IP67
h ~ 44 mm (+ 20 mm
bend relief)
cable length ~ 2 m
d ~ Ø 22 mm
Ordernumber: 011
d
h
Installation
Couple de serrage
selon letage
NPT 1/8; M 10 x 1 conique
18 Nm maxi
M 10 x 1 cyl.; G 1/8
20 Nm maxi
M 12 x 1.5; 7/16 – 20 UNF
30 Nm maxi
G 1/4; 9/16 – 18 UNF
40 Nm maxi
NPT 1/4; M 14 x 1.5
40 Nm maxi
Removing
CE Mark
Key to drawings:
Caution
Danger
Subject to technical changes without notice.
M 12–DIN EN
ISO 15170-A1-4.1
61076-2-101-A
1
2
4
2
3
1
3
4
2
0660
0645 + 0650
0660
0645 + 0650
0690
0675 + 0680
0690
0675 + 0680
1: U
1: U
1: U
1: U
v+
v+
v+
v+
2: I
2: U
2: nc
2: Gnd
Out
Out
3: nc
3: Gnd
3: I
3: U
Out
Out
4: nc
4: nc
4: nc
IP67
h ~ 54 mm
d ~ Ø 22 mm
d ~ Ø 27 mm
Ordernumber: 002
Ordernumber: 004
1: red
2: white
3: black
Thread code:
41
0660
0690
1: U
v+
2: nc
3: I
Out
1
(1) Electrical connection
(2) Hydraulic / pneumatic connection
(h) Height
hex 22
2
Mechanical, pneumatic, hydraulic:
Screw the electronical pressure transmitter
Thread
into the pressure connection provided using
an open-jaw spanner of 22 AF size (as per
NPT 1/8; M 10 x 1 conical
DIN 894 or similar).
M 10 x 1 cyl.; G 1/8
To seal the system, use a proper gasket
M 12 x 1.5; 7/16 – 20 UNF
relating to the individual thread. For threads
G 1/4; 9/16 – 18 UNF
with integrated sealing ring no additional
sealing is necessary.
NPT 1/4; M 14 x 1.5
Electrical:
Ensure that the position of the seal of individual connectors is correct
mounted and the Pg gland (at DIN EN175301- A) is properly fi tted, as
otherwise the enclosure IP-class cannot be achieved.
Pay particular attention while wiring the connector DIN EN 175301-A:
– cable connections as per diagram
– cables routed without crushing
– Pg gland screwed with ca. 20 cNm
Please bear in mind the following when removing the pressure transmitter:
• Before the electronic transmitter switch is removed, the system must be
depressurized
• All the relevant safety regulations must be complied with.
• Unscrew the pressure transmitter out of the pressure connection using
an open-jaw spanner of 22 AF size (as per DIN 894 or similar).
Electronic pressure trans-
mitters
from
SUCO
fall
within the scope of directive
2014/30/EU
EMC.
EC
declarations of conformity
have been issued for the
electronic
pressure
are
available on request or can
be downloaded from our
website. The devices are
denoted by a CE mark.
Note
Recycling
Danger
Elektrische Anschlüsse und Gewinde
DIN EN 175301-803-A
1
2
PE
3
1
3
0660
0645 + 0650
0660
0675 + 0680
0690
0690
1: U
1: U
1: U
v+
v+
v+
2: Gnd
2: I
2: nc
Out
3: U
3: nc
3: I
Out
Out
PE
4: nc
IP65
IP67
h ~ 60 mm
(ohne Gerätesteckdose)
h ~ 65 mm
h ~ 76 mm
(mit Gerätesteckdose)
d ~ Ø 30 mm
Bestellnummer: 013
Kabelanschluss
1: rot
2: weiß
3: schwarz
0645 + 0650
0660
0675 + 0680
0690
1: U
1: U
v+
v+
2: U
2: nc
Out
3: Gnd
3: I
Out
IP67
h ~ 44 mm (+ 20 mm
Knickschutz)
Kabellänge ~ 2 m
d ~ Ø 22 mm
Bestellnummer: 011
d
h
Einbau
Tightening
Mechanisch, pneumatisch, hydraulisch:
torque
Drehen Sie den Drucktransmitter mit einem
max. 18 Nm
Maulschlüssel der Schlüsselweite 22
max. 20 Nm
(nach DIN 894 o.ä.) in den vorgesehenen
Druckanschluss.
max. 30 Nm
Zum Abdichten des Systems verwenden
max. 40 Nm
Sie eine für das jeweilige Gewinde geeignete
max. 40 Nm
Dichtung. Für Gewinde mit integriertem
Dichtring ist keine zusätzliche Dichtung
notwendig.
Elektrisch:
Achten Sie auf die ordnungsgemäße Lage der Dichtungen der jeweiligen
Steckverbindung und auf eine sachgemäße Montage, da sonst die IP-
Schutzart nicht erreicht wird.
Bitte beachten Sie beim Anschlagen der Leitung in der Gerätesteckdose
DIN EN 175301-A:
– Verkabelung nach Anschlussbild
– Quetschfreie Kabelführung
– Pg-Verschraubung (mit ca. 20 cNm) anziehen.
Ausbau
Beachten Sie folgende wichtige Punkte beim Ausbau des
Drucktransmitters:
• Das Drucksystem, aus dem der Drucktransmitter ausgebaut werden soll,
muss sich im drucklosen Zustand befi nden.
• Es müssen alle relevanten Sicherheitsbestimmungen beachtet werden.
• Drehen Sie den Drucktransmitter mit einem Maulschlüssel der
Schlüsselweite 22 (nach DIN 894 o.ä.) aus dem Druckanschluss.
CE Kennzeichnung
Elektronische Drucktransmit-
ter von SUCO fallen unter
die EMV-Richtlinie 2014/30/
EU. Für die elektronischen
Drucktransmitter
EG
Konformitätserklärung
ausgestellt
kann
angefordert
von
unserer
heruntergeladen
Die Geräte sind mit dem CE-
Zeichen gekennzeichnet.
Zeichenerklärung:
Achtung
Hinweis,
Bemerkung
Technische Änderungen zur Produktverbesserung vorbehalten.
M 12–DIN EN
ISO 15170-A1-4.1
61076-2-101-A
1
2
4
3
4
2
0645 + 0650
0660
0645 + 0650
0660
0675 + 0680
0690
0675 + 0680
0690
1: U
1: U
1: U
1: U
v+
v+
v+
v+
2: U
2: nc
2: Gnd
2: nc
Out
3: Gnd
3: I
3: U
3: I
Out
Out
Out
4: nc
4: nc
4: nc
4: nc
IP67
IP67
h ~ 54 mm
h ~ 65 mm
d ~ Ø 22 mm
d ~ Ø 27 mm
Bestellnummer: 002
Bestellnummer: 004
Gewindeschlüssel:
41
1
(1) Elektrischer Anschluss
(2) Hydraulischer / pneumatischer Anschluss
(h) Höhe
SW 22
2
Gewindebezeichnung
Anzugs-
drehmoment
NPT 1/8; M 10 x 1 kegelig
max. 18 Nm
M 10 x 1 zyl.; G 1/8
max. 20 Nm
M 12 x 1,5; 7/16 – 20 UNF
max. 30 Nm
G 1/4; 9/16 – 18 UNF
max. 40 Nm
NPT 1/4; M 14 x 1,5
max. 40 Nm
ist
eine
und
diese
oder
Internetseite
werden.
Recycling
Gefahr
1
3

Publicité

loading

Ce manuel est également adapté pour: