Ac Volts (True Rms) - Weidmüller 2608C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
DC Volts
Resolution
Range
660mV
6.6V
66V
660V
1000V
Overload protection: 1000V DC or 750V AC rms

AC Volts (True RMS)

Range
Resolution
660mV
0.1mV
1mV
6.6V
10mV
66V
660V
100mV
750V
Crest Factor: ≤ 3
Peak Hold: ±(3.0% rdg + 200 dgts) on 66V to 750V ranges
AC coupled true rms specified from 5% to 100% of range
FREQUENCY Ranges: 50Hz ~ 1kHz.
Accuracy: ± (0.1% rdg + 5 dgts)
Minimum Input voltage Range: >500dgts.
The readings of frequency measurements will show on the sub-
display.
Overload protection: 1000V DC or 750V AC rms
2608C.p65
Accuracy
0.1mV
± (0.5% rdg + 2d)
1mV
± (0.5% rdg + 2d)
10mV
± (0.5% rdg + 2d)
100mV
± (0.5% rdg + 2d)
1V
± (0.5% rdg + 2d)
Accuracy (50~500Hz)
± (1.5% rdg + 8d) 50~100Hz
± (1.5% rdg + 8d) 50~500Hz
± (1.5% rdg + 8d) 50~500Hz
± (1.5% rdg + 8d) 50~500Hz
1V
± (1.5% rdg + 8d) 50~500Hz
31
31
Input Impedance
>100MΩ
10MΩ
9.1MΩ
9.1MΩ
9.1M Ω
Input Impedance
> 100MΩ
10MΩ
9.1MΩ
9.1MΩ
9.1MΩ