INSTRUCTIONS FOR ThE RECOVERy OF CONTAMINATED FlUShING lIQUID
1) Change the setting of the tap 3 located on the back of Easy-Flush to recover the contaminated liquid.
We recommend cleaning the filter of Easy-Flush every 10 flushing operations.
1) Unscrew the filter housing 1 placed on the side of Easy-Flush.
2) Remove the inner filter.
3) Proceed to the washing of the filter by immersing it for 3 minutes in a container filled with flushing liquid for A/C system.
4) Blow with compressed air.
5) Replace the filter.
Reproduction, even partial, in any form of this handbook without prior written consent by ERRECOM srl is strictly prohibited.
ERRECOM srl reserves the right to improve or modify its equipments at any time and without prior notice.
INSTRUCTIONS FOR ClEANING ThE FIlTER
3
1
ENGLISH
IST.VP1027.01