13. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may
cause fire, electric shock, or injury to persons.
14. Should the air intakes become blocked during operation the unit will shut down and remain off. To reset:
Unplug heater, ensure all intakes are free of obstructions, and let unit cool for 10 minutes before restarting.

Safety Feature

This model has two-stage overheat protection: a manual reset thermostat and a one-time thermal fuse. If the
flow of air becomes blocked, the heater will automatically turn off when the internal temperature reaches
~55°C. The unit will remain off.
To reset: Unplug heater, ensure all intakes are free of obstructions, and let unit cool for 10 minutes before
restarting.

Care and Maintenance

15. Both filters should be cleaned (either by vacuum or under running water) once a month if the heater is
under continuous use for a month. Do NOT use filter if wet; allow to dry before reaffixing to the heater.
16. Unplug the heater and using a vacuum, clean the air intakes on the top and bottom of the unit as well as
the front grill.
17. Replace provided filters if damaged or torn. Use MediHeat filters only.
18. Do not attempt to service the heater. Your heater has been designed for many years of problem-free
operation. The motor is permanently lubricated and does not require oiling. However, since this model
moves a high volume of air, it does require periodic cleaning.
Specifications
120 Volts, 60 Hz, 13.2 Amps, 900 and 1500 Watts (3,000 and 5,100 BTU/HR), 6 ft. cord (1.83 m)