Installation Instructions - Intergrated Application
Tools You Will
Need
FOR YOUR SAFETY
While performing
installations described in
this section, gloves, safety
glasses or goggles should
be worn.
Preparing the
Enclosure
Electrical Requirements:
The appliance must be
connected to an individual
properly grounded electrical
outlet, protected by a 15 or
20 ampere circuit breaker or
time delay fuse.
IMPORTMANT !
Door Swing
Door Swing
Do not include the door
Do not
within the enclosure;
leave it outside of the
enclosure to prevent the
door swing from being
obstructed.
*The listed depth requirement for the installation is assuming that the electrical outlet is located in the
adjacent cabinetry or is flush mounted in the rear wall, not surface mounted in the enclosure.
Safety Glasses
Gloves
Drill & Hole Saw Set
• It is recommended that you do
not install the Wine Cooler
into a corner (i.e. directly beside
a wall). This is to allow the
door(s) to have a greater then
90° opening swing. A limited
door swing will prevent the
shelves from sliding out as
intended, and may lead to dam-
aging the door gasket(s).
• The rough cabinet opening
must be on a level floor area
and at least 23 7/8" deep
(60.24cm) by 15"(38.1cm)
wide. The opening should also
have a height of at least
34 1/16"(86.52cm).
Fig D
8
Level
Flashlight
Carpenters
Square
Measuring
Tape
• The electrical outlet may be
positioned from within either
side of the adjacent cabinetry , or
the rear of the shaded area (as
shown in Fig D).
Important
Important
If the electrical outlet
is surface mounted (not flush)
within the enclosure, the depth
requirement for the installation
may be affected.
• If the electrical outlet is located
inside the adjacent cabinetry, cut
a 1-1/2"(3.81cm) diameter hole to
admit the power cord. If the cabi-
net wall is metal, the hole edge
must be covered with a bushing
or grommet.
Fig D
1 237/8" min. depth
2 341/16" from underside
of countertop to floor.
3 15" min. width
4 2" of depth given
for Elec. Access*
5 1 1/2" dia. hole (if
outlet is inadjacent
cabinetry).
6 Cabinets square
and plumb

Publicité

Chapitres

Table des Matières
loading