Display and Alarm – the Logo LED functions
The mode is indicated by the color of the Logo LED as follows:
1.
Blue – automatic mode. Indicates good air quality and normal fan speed of 20%
2.
Red – automatic mode. Indicates poor air quality and high fan speed of 100%
3.
Green – manual mode. Fan power can be set to 3 speeds; low 20%, medium 50%, or
high 100%
4.
Red, flashing continuously – indicates reactor cell replacement is due.
Remote control
Automatic Operation Mode:
When the unit is switched on, either by the power switch on body
or the on/off button on the remote control, the product is in auto-
matic mode. Blue LED lights are displayed and the fan speed is nor-
mal (20%). If dust, germs or VOC's are detected by the sensor, the
fan switches to full power and red LED lights are displayed. When
the dust, germ or VOC levels return to healthy levels, the unit au-
tomatically returns to 20% fan speed and displays the blue color.
Note - When the unit is switched on the Indoor Air Quality (IAQ)
sensor takes up to 5 minutes to calibrate.
Manual Operation Mode:
If you wish to manually control the fan speed, press the manual button on the remote control.
The green LED light is displayed to indicate manual mode. Press "speed" "+" or "–" to change
the fan speed. The settings are low 20%, medium 50% and high 100%.
Manual mode
Press "MANUAL" button.
Adjust speed
Press "SPEED"
"+" or "–" button".
Sleep Mode:
When sleep button is
pressed, the fan switches to
very low (10%) and all LED
lights are switched off.
Press
"on/off"
button
Indirect LED Light
In addition to the Logo LED,
there are also indirect LED lights
inside Hextio. When the LED
button is pressed, the indirect
LEDs are switched off or on.
7