SWITCH SELECTOR ACCESSORY WITH TIMER
9730057 ASC-051 SWITCH SELECTOR ACCESSORY WITH TIMER
Accesory with wich to operate additional elements by means of a control signal. It is possible
to set the period of time for activation once the control signal has ceased. Has two ranges
of time settings and can be activated with:
- The SC1 signal of the audio unit, pushbuttons.
- The electronic call.
- Direct current (DC) external signals.
Applications: Activating devices with the auxiliary push-button of the digital telephone, setting
times for door opening, etc.
The switch selector accessory can be fixed to
the flush-mounted box or to a wall using the
rawlplugs and screws provided.
DOOR ENTRY SYSTEMS
ASSEMBLY INSTRUCTIONS
C 2
C 1
O 2
1 N
N O
C 2
1 N
N C
l
C tr

Publicité

loading

Sommaire des Matières pour Alcad ASC-051

  • Page 1 DOOR ENTRY SYSTEMS SWITCH SELECTOR ACCESSORY WITH TIMER 9730057 ASC-051 SWITCH SELECTOR ACCESSORY WITH TIMER Accesory with wich to operate additional elements by means of a control signal. It is possible to set the period of time for activation once the control signal has ceased. Has two ranges of time settings and can be activated with: - The SC1 signal of the audio unit, pushbuttons.
  • Page 2 DOOR ENTRY SYSTEMS SETTING TIMES FOR SECOND DOOR OPENING FROM DWELLING - DIGITAL SYSTEM WITH PUSH-BUTTONS FROM THE MONITOR - Note: To connect the door entry system, look up in the technical datasheet that comes with the audio unit.
  • Page 3 DOOR ENTRY SYSTEMS FROM THE TELEPHONE - Note: To connect the door entry system, look up in the technical datasheet that comes with the audio unit. Operation When the monitor auxiliary button is pressed, the circuit of the control signal (15Vdc) is closed through terminal 25 (+).
  • Page 4 DOOR ENTRY SYSTEMS SETTING TIMES FOR SECOND DOOR OPENING FROM DWELLING - CONVENTIONAL SYSTEM FROM THE MONITOR - Note: To connect the door entry system, look up in the technical datasheet that comes with the audio unit.
  • Page 5 DOOR ENTRY SYSTEMS FROM THE TELEPHONE - Note: To connect the door entry system, look up in the technical datasheet that comes with the audio unit. Operation When the monitor or the telephone auxiliary button is pressed, the circuit of the control signal (15Vdc) is closed through terminal 25 (+), allowing power to be supplied to the second door for a pre-established period of time (see timing in adjusting instructions).
  • Page 6 DOOR ENTRY SYSTEMS SETTING TIMES FOR DOOR OPENING FROM INSIDE - DIGITAL SYSTEM Push-button Note: To connect the door entry system, look up in the technical datasheet that comes with the audio unit. Operation When the pushbutton is pressed, the circuit of the control signal (15Vdc) is closed through this pushbutton, allowing the circuit between terminals 22 and 18 to be closed and for power to be supplied to the electric lock for a pre-established period of time (see timing in adjusting instructions).
  • Page 7 DOOR ENTRY SYSTEMS TIME SETTING FOR DOOR OPENING FROM INSIDE - CONVENTIONAL SYSTEM Push-button Note: To connect the door entry system, look up in the technical datasheet that comes with the audio unit. Operation When the pushbutton is pressed, the circuit of the control signal (15Vdc) is closed through this pushbutton, allowing the circuit between terminals V and 12 to be closed and for power to be supplied to the electric lock for a pre-established period of time (see timing in adjusting instructions).
  • Page 8 DOOR ENTRY SYSTEMS AUTOMATIC DOOR-OPENING ON CALLING A DWELLING – DIGITAL SYSTEM Important: Ensure that the polarity of D1, D2 Audio unit between the telephone and the connections bracket is respected. Note: To connect the door entry system, look up in the technical datasheet that comes with the audio unit.
  • Page 9 DOOR ENTRY SYSTEMS AUTOMATIC DOOR-OPENING ON CALLING A DWELLING – CONVENTIONAL SYSTEM Note: To connect the door entry system, look up in the Audio unit technical datasheet that comes with the audio unit. Operation The call to the dwelling is used as the control signal, allowing the circuit between terminals 1 and 2 of the system to be closed and for power to be supplied to the electric lock for a pre- established period of time (see timing in adjusting instructions).
  • Page 10: Adjustment Instructions

    DOOR ENTRY SYSTEMS ADJUSTMENT INSTRUCTIONS Time-setting To adjust the time-setting of the accessory, it must be borne in mind that the time-setting begins when the control signal appears. Two ranges of time-setting are available, depending on whether the J1 jumper is connected or not. Either insert or extract the J1 jumper to select the time-setting range required.
  • Page 11 DOOR ENTRY SYSTEMS Set the time period using the time-setting control. Note: If the control signal is still being sent after the set time has expired, the accessory will remain activated until the control signal stops.
  • Page 12: Connection Instructions

    DOOR ENTRY SYSTEMS CONNECTION INSTRUCTIONS ACTIVATED BY THE AUXILIARY PUSH-BUTTON OF THE TED-002 Time-setting control Time-setting range Power supply Audio unit Additional Elements Deactivation signal...
  • Page 13 DOOR ENTRY SYSTEMS STATE OF THE CONTACTS STATE OF THE CONTACTS ACTIVATION TERMINALS AT REST WORKING Operating temperature - The contacts will return to the stand-by position once the set time has expired and there is no longer a control signal.
  • Page 14 DOOR ENTRY SYSTEMS ACTIVATING BY EXTERNAL SIGNAL Time-setting control Time-setting range Audio unit / Power supply Additional Elements Deactivation signal STATE OF THE CONTACTS IN RELATION TO THE CONTROL SIGNAL STATE OF THE CONTACTS ACTIVATION TERMINALS AT REST WORKING Operating temperature - The contacts will return to the stand-by position once the set time has expired and there is no longer a control signal.
  • Page 15 DOOR ENTRY SYSTEMS TERMINALS Power supply Audio unit push-buttons control signal - Control signal Control signal Deactivation signal Time-setting range selector Circuit Common - Normally open contact Normally closed contact Characteristics Maximum values of the control circuit: 5 A - 250 V AC. Switch...
  • Page 16 DOOR ENTRY SYSTEMS 18-10-07...