• Install energizer where it can get plenty of sunlight.
• Keep solar panel surface clean - periodically use a so cloth with water and a
mild detergent.
• Test voltage on the fence using a Gallagher Fence Volt Meter (G50301).
Problem
Indicator fl ashing red
Indicator fl ashes red
twice when turned on
then stops
No voltage on fence
Note: Approvals & Standards - FCC
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protec on against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruc on manual, may cause
harmful interference to radio communica ons. Opera on of this equipment in a residen al
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
10
Solu ons
Ensure energizer is ge ng enough sun
Turn energizer OFF for 3 days, leave in the sun to
charge ba ery.
Remove ba ery and use a 6 V 1.2 A charger to
charge ba ery.
Perform above steps
Replace ba ery
Check energizer isn't faulty;
-
disconnect from fence and earth
-
measure across fence and earth terminals
with a Gallagher Fence Volt Meter
-
if less than 5 kV return energizer for service
-
if more than 5 kV the fault is with the fence or
earth system.