SECTION 5. OPERATING INSTRUCTIONS
Switch power on at the fused spur.
Pushbutton Functions
Motor RUN ON TIMER
(OFF after 10 minutes to clear fumes)
Motor ON –INTENSIVE MODE
(Reverts to speed 3 after 5 mins)
Motor ON - SPEED 3
(Maximum Speed for Normal Use)
Motor ON - SPEED 2
Motor ON - SPEED 1
Remote Control Functions
Function Press
LEDs
Lights
ON/OFF
Motor ON
Speed 1/
Motor OFF
The extractor controller will automatically switch off
the appliance if there has been no operator action for
4 hours.
After 30 hours accumulated running, GREASE FILTER
CLEANING will be signalled by all 6 indicators flashing.
Reset by pressing RUN ON TIMER Pushbutton.
SECTION 6. MAINTENANCE
Regular maintenance is essential to ensure good
performance and long-life.
To maintain the immaculate appearance of the extractor,
and to minimise fire risk, ensure that grease deposits on
the extractor surfaces are kept to a minimum by regular
cleaning.
AGA Cooker Hood PH890/PH990/PH1090
Motor OFF
Lights ON/OFF
INCREASE SPEED
Speeds 2, 3, 4
RUN ON TIMER
(MOTOR OFF after 10
minutes to clear fumes)
DECREASE
SPEED (2 min)
W1702 AGA PH Cooker Hood IO&M Oct 2019.docx
To clean the stainless steel surfaces of the extractor, use
a soft cloth and a suitable cleaning agent, such as a
specially produced stainless steel cleaner or washing up
detergent and warm water.
Painted surfaces should be cleaned using a soft cloth,
detergent and warm water.
Do not use abrasive cleaning materials or products
on any hood surfaces.
Do not use bleach-based cleaning products on any
hood surfaces.
Clean the grease filters in a dishwasher or by hand-
washing in hot water and detergent. Wash the filters at
least every 2 months - sooner if the extractor is used
extensively and filters become grease laden.
Whilst you can expect years of service from your grease
filters, they are considered a consumable item and may
deteriorate over time and need replacement, particularly
when cleaned in a dishwasher.
For all users, filters should be replaced whenever they
exhibit signs of physical wear.
To remove the grease filters, pull the filter release lever
away from the hood base, releasing the sprung latch,
allowing the filter to be lifted away from the hood. Care
should be taken not to scratch the hood.
LED lamps require no end user maintenance.
SECTION 7. SPECIFICATIONS
Blower airflow, nominal:
Supply voltage:
LED lamp voltage:
Blower power input:
Lamp power:
Fuse size for electrical supply:
Blower spigot diameter:
Approximate Hood Weights:
For detailed specification and energy efficiency
information please refer to the product fiche for your
hood.
800 m3/hr
230V~ 50Hz
12V
1 @ 275W
3 x 2.6W
3A
150mm
PH890
31Kg
PH990
34Kg
PH1090
37Kg
4