Location Requirements
Product Dimensions
¹⁄₈
34
"
(86.7 cm)
(38.1 cm)
Cutout Dimensions
A
24" min.
(61 cm)
A. Grounded electrical outlet must be a minimum of
3" (7.6 cm) away from surrounding cabinets or
nearby walls as shown. It can be placed either to
the left or the right side of the compactor.
4
24"
15"
(61 cm)
3" min.
(7.6 cm)
¹⁄₄
34
" min.
(87 cm)
18" min.
(45.7 cm)
¹⁄₄
15
" min.
(38.7 cm)
Clearance Dimensions
B
A. Leave 6" (15.2 cm) of clearance space to the right side of the
compactor in order to remove the compactor bags.
B. Leave 23" (58.4 cm) of clearance in front of the compactor in
order to fully open or remove the compactor drawer.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Recommended Grounding Method
This compactor is for use on a single phase, 115-volt, 60 Hz, AC only,
15- or 20-amp fused and properly grounded circuit and is equipped
with a grounding plug as shown below. It is recommended that a
separate circuit serving only this appliance be provided.
This compactor must be grounded while in use to reduce the risk of
electric shock. The compactor is equipped with a three-conductor
cord and 3 prong grounding-type plug to fit the proper grounding-
type receptacle. The green (or green and yellow) conductor in the
cord is the grounding wire. Do not connect the green (or green and
yellow) wire to a live terminal.
A