Operating Mode - Daspi D-SPEED Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1 • GENERAL SAFETY INFORMATION ATTENTION: It is prohibited to carry out any kind of assembly, repair or adjustment to the apparatus by unqualified
EN
staff, and if the necessary precautions haven't been taken and electricity supply disconnected (including any back-up batteries), in order to avoid any
possible accident or injury, DASPI will not be responsible for any damage or injury to people, animals or objects resulting from improper use of the
apparatus or for use other than what is specified in this instruction booklet, and/or resulting from any modification carried out on this product and its components.
This control panel is not suitable for installation in an explosive atmosphere. Keep this manual with care, enclose it to the technical installation file and keep
them in a suitable an convenient place known by whoever is concerned, for future reference.
2 • PRODUCT TYPE The D-SPEED control panel is designed to control a 230 Vac 50/60 Hz motor for sliding gates. It is supplied with an electronic clutch, encoder,
obstacle detection system, slowing down, adjustable braking devices and a built-in radio receiver.
3 • TRIMMER
TRIMMER DESCRIPTION
For adjusting gate pause time before re-closing. Feature is active in Automatic, Residential and Condominium operating modes. Feature is not active in
TR1
Standard and Step by Step operating modes. From 2 to 140 seconds. Turning clockwise increases the pause time.
TR2
For adjusting motor torque from 20 to 100%. Turning clockwise increases the torque.
For adjusting the braking from 0 to 100% in the slowing down phases. Turning clockwise increases the braking. To disactivate braking feature the
TR3
trimmer must be turned fully anti-clockwise. Attention! Use only with very heavy gates from 1000 kg and over, or with considerable inertia.
For adjusting motor speed from 30% to 100% during slowing down. Turning clockwise increases the speed in slowing down. To disable the deceleration, the
TR4
trimmer must be turned fully clockwise.
For adjusting obstacle sensitivity. To increase the sensitivity rotate the trimmer counter-clockwise. To disable the feature rotate the trimmer completely
TR5
clockwise.
4 • DIP-SWITCH
SW1
FEATURE
DIP
Not used
1
2
Not used
3
Not used
4
Safety input
5
Pre-flashing
OPERATING MODES TABLE
Standard (default)
START command with:
DIP6
ON
Gate closed
Gate opening
Gate open with limit
switch engaged
Gate closing
Gate in Stop
(*) With automatic time closing feature enabled (not available in Standard and Step by Step modes)
(*) To activate additional feature "Close after passing through photocells" switch DIP8 ON (not available in Standard and Step by Step modes)
Each time dip-switch and trimmer positions are adjusted, control panel must be reset by turning off the power. (Disconnect the circuit breaker or remove the
fuse F2 or disconnect the power terminal block)
5 • LED
Always off, it turns on with OPEN command
DL1
DL2
Always off, it turns on with PED command
DL3
Always off, it turns on with START command
DL4
Always on, it turns off with STOP command
DL5
Always on, it turns off with PHOTO command
Make sure that all N.C. contacts (normallyclosed contacts) are switched on. If not , double check that installed devices are working properly and powered.
Remember that if a normally closed contact is not used, it must be bridged. If no LED is lit on, check electricity mains, then check that the fuses are working, Make
sure that LEDs of all N.O. contacts (normally-open contacts) are swiched off. If not, double check that installed device are working properly.
6 • STORING REMOTE CONTROLS
The D-SPEED control panel has a built-in radio receiver that can store up to 128 rolling code remote controls or 30 fixed code remote controls.
POPS model remote controls are not compatible.
Storing a remote control.
1 - Press P2 button and hold it down until the led DL9 begins flashing.
2 - Release button P2.
3 - Press the button of the remote control to be stored. Proper storing will cause the end of LED DL9 flashing. If after 10 seconds a remote control is not stored,
storing procedure will be terminated automatically.
ON
OFF
--
--
--
--
--
--
Safety edge
Photocell 2
Enabled
Disabled
Automatic (*)
DIP7
DIP8
DIP6
DIP7
OFF
OFF
OFF
ON
Gate Stops
Gate Stops
Gate Closes
Gate Closes
Gate Opens
Gate Opens
Gate Closes
Gate Closes

OPERATING MODE

Residential (*)
DIP8
DIP6
DIP7
DIP8
OFF
ON
ON
OFF
Gate Opens
Command Ignored
Gate Closes
Gate Opens
-
Always on, it turns off with SAFETY command
DL6
DL7
Always on, it turns off with LSO command (opening limit switch)
DL8
Always on, it turns off with LSC command (closing limit switch)
DL9
Always off, it turns on or flashes during programming
or remote code storing procedure.
Condominium (*)
DIP6
DIP7
DIP8
DIP6
OFF
OFF
OFF
ON
Command Ignored
Gate Restarts
the pausing time
Gate Opens
-
Step by Step
DIP7
DIP8
OFF
ON
Gate Stops
Gate Closes
Gate Stops
Gate Closes