ENVIRONMENTAL CONDITIONS
TEMPERATURE:
RELATIVE HUMIDITY
ALTITUDE
WORKPLACE REQUIREMENTS
ENVIRONMENT:
Non-explosive.
Non-corrosive.
There must be no sudden changes in temperature.
Protected from atmospheric agents and from direct contact with water.
LIGHTING:
Diffused, as it must not create cones of shadows on the outside of the machine or create blinding
flashes or stroboscopic effects.
SUPPORT SURFACE:
Horizontal and smooth
It must support the weight of the model at hand (see the table in FIG. 6) in addition to previously
existing loads.
ELECTRICAL CONNECTION
230/400 V, 50 Hz power supply with a maximum variation of ± 10% for voltage and ± 1% for frequency.
The power lines must be sized for a correct rated voltage according to the model (see the table in FIG. 6),
protected against overloads, short circuits, and indirect contacts (protector differential + conductor) and with
drop in voltage equal to ± 1% of the mains voltage.
N.B. read the attached electrical/technical documentation.
TRANSPORT AND POSITIONING
The machine is shipped completely assembled and in a single package. For shipping from the manufacturer,
the machine is placed on a pallet and secured and, if necessary or required by contract, packed in a thick
cardboard (box) or wooden container (cage). While handling/transporting the machine, take every precaution
to avoid, or limit, the possibility of risk for persons or property.
The loading onto/unloading from the means of transport is usually done with a forklift/ transpallet truck with
an adequate capacity (see the table in FIG. 6); the arms must be inserted into the special spaces at the base of
the pallet.
INSTALLATION
1)
Open the wooden crate used for the transportation (if present).
2)
Remove the protective nylon film from the machine.
3)
Release the machine from its anchorings to the pallet.
4)
Lift the machine with lifting cables tied under the head and deposit it in the installation site.
5)
Guarantee a minimum distance of 30 cm from any machine or wall.
6)
Ensure that the machine is set perfectly onto the floor, regulating the 4 nuts under the base if necessary
to anchor the stabilizing feet firmly to the ground.
7)
Connect the electrical power supply plug to the outlet made available by the buyer.
8)
Check that the sense of rotation of the tool is correct (see the specific arrow); if it is rotating in the
opposite direction, stop the machine immediately and invert the phase of the power supply plug (only
specialised personnel are allowed to carry out this operation).
min. -5°C max. 40°C
max. 50% at 40°C
max. 1000 m.
ENGLISH
19