Velleman DCM140 Mode D'emploi page 13

Cat iii 600 v

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
1.
Connect the black test lead to the "COM" jack and the red test lead to
the input jack.
2.
Set the selection switch to the desired "
3.
Press the SEL function button to select "
4.
Connect the test leads across the source under measurement.
5.
Read the value on the LCD display.
10.6 CONTINUITY TEST
Do not conduct continuity measurements on live circuits. Make sure
all capacitors in the circuit are depleted.
1.
Connect the black test lead to the "COM" jack and the red test lead to
the input jack.
2.
Set the selection switch to the desired "
3.
Press the selection button to choose the " " measurement.
4.
Connect the test leads to two points of the circuit to be tested. If
continuity exists, the built-in buzzer will sound.
10.7 TEMPERATURE MEASUREMENT
1.
Connect the black test lead to the "COM" jack and the red terminal of
the K-type temperature probe to the input jack.
2.
Set the selection switch to the desired "°C/°F" position.
3.
Press the selection button to choose the "°C" or "°F" measurement.
4.
Place the temperature probe across the source under measurement.
5.
Read the voltage value on the LCD display.
10.8 NCV (NON-CONTACT VOLTAGE) MEASUREMENT
Due to external interference sources, thus function may cause wrong
voltage detection. Use the results as reference only.
1.
Set the selection switch to the desired "NCV" position.
2.
Contact the top part of the meter across the source under
measurement. The LED will flash and the audible signal will sound if
voltage is detected.
3.
Read the signal on the LCD display.
10.9 LINE (LIVE WIRE RECOGNITION) TEST
1.
Connect the black test lead to the "COM" jack and the red test lead to
the input jack.
2.
Set the selection switch to the desired "LINE" position.
V. 01 – 26/02/2019
DCM140
" measurement.
13
" position.
" position.
©Velleman nv