Télécharger Imprimer la page

GE 106575 Manuel Du Propriétaire page 10

Publicité

Les langues disponibles

Les langues disponibles

How to Check and Clear Hose Blockages
Low suction or poor pickup may be due to a blockage in the vacuum cleaner.
1. Remove hose from hose retainer and check suction at
end of hose - if little or no suction, check disposable
dust bag. Change if needed. If no improvement proceed
to step 2.
CAUTION: Turn off the switch and unplug the electrical
cord before clearing hose.
2. Remove electrical cord from cord hooks. Disconnect
the clear tube by turning quarter turn fastener to the
right to release, then lift away from cleaner.
Check for any obstructions that may be in the tube.
Any obstructions can be removed by using a blunt
instrument to clear the tube.
3. To completely release hose from the unit, remove two
screws.
Any obstructions can be removed by using a blunt
instrument to clear the hose. Flexing the hose may help
loosen the blockage.
After clearing blockage, reverse above steps to reassemble
unit.
Quarter
Turn
Fastener
2
Clear
Tube
2. Disconnect Clear Tube.
10
All manuals and user guides at all-guides.com
1. Remove hose from hose retainer and
check suction at end of hose.
Two Screws
3
3. Release hose from unit.
Electrical
Cord
Hose
Retainer
1

Publicité

loading