Avoid pointing the detector towards objects
that may move in the wind such as
curtains, plants, etc.
Install the detector at a distance of
minimum 60 cm when using a lamp of 60 W
or more.
Do not install the detector directly below a
light source.
Installation
Install this detector flat on a wall or in a
corner. Use an appropriate screwdriver and
the included screws and nylon plugs.
1.
Open the device by turning the upper
cover.
2.
Connect the detector (see below) and
fix the bottom.
3.
Re-install the upper cover to close the
detector.
Connection Guidelines
Risk of electroshock! Touching live wires
can cause life-threatening electroshocks.
 Have the device installed by qualified
personnel.
 Disconnect the power source.
 Cover and shield any adjacent live
components.
 Ensure the device cannot be switched on.
 Make sure the power supply is
disconnected.
See illustration on page 3.
1.
220-240 V~, 50 Hz power supply
2.
load
E300LS