S102.5, S102.6, and S102.7. The auto-speed feature is only
applicable when the dome is being controlled by a system
generating "fixed speed" commands.
S102.1: RS-232 Baud rate: 2400 - OFF, 9600 - ON
S102.2: Lens Zoom Polarity: Normal - OFF, Revesrse - ON.
S102.3: Lens Focus Polarity: Normal - OFF, Revesrse - ON.
S102.4: Lens Iris Polarity: Normal - OFF, Revesrse - ON.
S101.1: Reserved, set to OFF
S101.2: Reserved, set to OFF
S101.3: Reserved, set to OFF
S101.4: Not defined, set to OFF
S101.5: Not defined, set to OFF
S101.6: Not defined, set to OFF
S101.7: Not defined, set to OFF
S101.8: Not defined, set to OFF
5.5

Site Address Thumbwheel Switch

Setting address selector to 0000 responds to all messages
regardless of address; otherwise the unit will only respond to
commands issued for that address.
DIP Switches and Site Address Thumbwheel Shown With
Power Supply Removed