3. Function Selection

Function selection of remote controller
The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed.
Item 1
1. Change Language
Language setting to display
("CHANGE
LANGUAGE")
2. Function limit
(1) Operation function limit setting (operation lock) ("LOCKING
("FUNCTION
FUNCTION")
SELECTION")
(2) Operation mode skip setting ("SELECT MODE")
(3) Temperature range limit setting ("LIMIT TEMP FUNCTION")
3. Mode selection
(1) Remote controller main/sub setting ("CONTROLLER MAIN/
("MODE
SUB")
SELECTION")
(2) Use of clock setting ("CLOCK")
(3) Timer function setting ("WEEKLY TIMER")
(4) Contact number setting for error situation ("CALL.")
(5) Temp off set setting ("TEMP OFF SET FUNCTION")
4. Display change
(1) Temperature display °C/°F setting ("TEMP MODE °C/°F")
("DISP MODE
(2) Water temperature display setting ("WATER TEMP DISP
SETTING")
SELECT")
Function selection flowchart
[1] Stop the unit to start remote controller function selection mode.
[5] Setting completed.
[6] Change the display to the normal one. (End)
Normal display (Display when
the unit is not running)
(Hold down the E button and press the D button for two
seconds.)
* The display cannot be changed during the test run and
the self diagnosis.
Item 1
Press the G button.
Change Language
("CHANGE LANGUAGE")
Press the
Operation function limit setting ("LOCKING FUNCTION")
E button.
Function limit
Operation mode skip setting ("SELECT MODE")
("FUNCTION
Press the
SELECTION")
G button.
Temperature range limit setting ("LIMIT TEMP FUNCTION")
Remote controller main/sub setting ("CONTROLLER MAIN/SUB")
Press the
Press the
E button.
E button.
Use of clock setting ("CLOCK")
Press the
Mode selection
G button.
Timer function setting ("WEEKLY TIMER")
("MODE
SELECTION")
Press the
Contact number setting for error situation ("CALL.")
E button.
Temp off set setting ("TEMP OFF SET FUNCTION")
Press the
Temperature display °C/°F setting ("TEMP MODE °C/°F")
Display change
G button.
("DISP MODE
SETTING")
Water temperature display setting ("WATER TEMP DISP SELECT")
Item 2
[2] Select from item 1.
(Hold down the E button and press
the D button for two seconds.)
* The remote controller records the
Remote Controller Function
Selection Mode
Item 2
Press the G button.
Press the G button.
Press the G button.
Item 3 (Setting content)
Display in multiple languages is possible
Setting the range of operation limit (operation lock)
Setting the use or non-use of each operation mode
Setting the temperature adjustable range (maximum, minimum)
Selecting main or sub remote controller
* When two remote controllers are connected to one group, one controller
must be set to sub.
Setting the use or non-use of clock function
Setting the timer type
Contact number display in case of error
Setting the telephone number
Setting the use or non-use of setback amount setting
Setting the temperature unit (°C or °F) to display
Setting the use or non-use of the display of water temperature
[3] Select from item 2.
[4] Make the setting. (Details are specified in item 3)
setting that is made in this way.
See [3]–1
Item 3
(Setting content)
See [3]–2. (1)
Press the
D button.
See [3]–2. (2)
See [3]–2. (3)
Press the
D button.
See [3]–3. (1)
See [3]–3. (2)
See [3]–3. (3)
See [3]–3. (4)
See [3]–3. (5)
Press the
D button.
See [3]–4. (1)
See [3]–4. (2)
NOTE
Timer operation stops when the display
for remote controller function selection is
changed to the normal one.
Dot display
The language that is selected in
CHANGE LANGUAGE mode
appears on this display. English
is set in this manual.
11

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

City multi pwfy-p36nmu-e2-auCity multi pwfy-p72nmu-e2-au

Table des Matières