8. Test run
E
8. Testlauf
D
Example
CENTRALLY CONTROLLED
CHECK
STAND BY
INDOOR UNIT
DEFROST
ADDRESS NO
Check code
CENTRALLY CONTROLLED
CHECK
STAND BY
INDOOR UNIT
DEFROST
ADDRESS NO
• For description of each check code, refer to the following table.
1 Check code
P1
Intake sensor error
P2
Pipe sensor error
P4
Drain sensor error
P5
Drain pump error
P6
Freezing / Overheating safeguard operation
P8
Pipe temperature error
P9
TH5 sensor error
U0–UP
Outdoor unit error
F1–FA
Outdoor unit error
E0–E5
Signal error between remote controller and indoor units
E6–EF
Communication error between indoor and outdoor units
– –
No alarm history
F F F F
No unit
• On wireless remote controller
2 The continuous buzzer sounds from receiving section of indoor unit.
3 Blink of operation lamp
• On wired remote controller
Press the remote controller's "CHECK" button twice consecutively to be able to run a self diagnosis.
Press the remote controller's "CHECK" button twice consecutively to be able to finish a self diagnosis.
1 Check code displayed in the LCD.
• Für Beschreibungen der einzelnen Prüfcodes siehe folgende Tabelle.
1 Prüfcode
P1
Einlaßsensor-Fehler
8
P2
Rohrsensor-Fehler
P4
Fehler des Abflußfühlers
P5
Fehler der Abflußpumpe
P6
Sicherheitsbetrieb gegen Einfrieren/Überhitzen
P8
Falsche Rohrtemperatur
P9
TH5 Sensorfehler
U0–UP
Fehler der Außenanlage
F1–FA
Fehler der Außenanlage
E0–E5
Signalfehler zwischen Fernbedienung und Innenanlage
E6–EF
Kommunikationsfehler zwischen Innen- und Außenaggregat
– –
Keine Alarmgeschichte
F F F F
Keine Einheit
• Bei der schnurlosen Fernbedienung
2 Dauersignalton von der Empfangseinheit der Innenanlage.
3 Blinken der Betriebsanzeige
• Bei der schnurgebundenen Fernbedienung
Drücken Sie zum Start des Selbsttests die Taste "CHECK" auf der Fernbedienung zweimal kurz nacheinander.
Drücken Sie zum Beenden des Selbsttests die Taste "CHECK" auf der Fernbedienung zweimal kurz nacheinander.
1 Überprüfen Sie den auf dem LCD angezeigten Code.
90
1Hr.
ON OFF
˚C
CLOCK
FILTER
˚C
CHECK MODE
ERROR CODE
FUNCTION
NOT AVAILABLE
OA UNIT ADDRESS NO
IC : Indoor unit
a)
OC : Outdoor unit
1Hr.
ON OFF
˚C
CLOCK
FILTER
˚C
CHECK MODE
ERROR CODE
FUNCTION
NOT AVAILABLE
OA UNIT ADDRESS NO
Unit address
Symptom
Symptom
Refrigerant address
CHECK
TEMP.
TEMP. button
TIMER SET
2 Buzzer sound
Single beep × 1
Single beep × 2
Single beep × 4
Single beep × 5
Single beep × 6
Single beep × 8
Single beep × 2
Double beep × 1
Double beep × 1
Sounds other than above
Sounds other than above
No sound
Triple beep
2 Signalton
Einzelner Piepton × 1
Einzelner Piepton × 2
Einzelner Piepton × 4
Einzelner Piepton × 5
Einzelner Piepton × 6
Einzelner Piepton × 8
Einzelner Piepton × 2
Doppelter Piepton × 1
Doppelter Piepton × 1
Andere Töne als die obigen
Andere Töne als die obigen
Kein Ton
Dreifacher Piepton
ON/OFF
FILTER
CHECK TEST
CHECK button
3 OPE LED
Lit for 1 sec. × 1
Lit for 1 sec. × 2
Lit for 1 sec. × 4
Lit for 1 sec. × 5
Lit for 1 sec. × 6
Lit for 1 sec. × 8
Lit for 1 sec. × 2
Lit for 0.4 sec. + 0.4 sec. × 1
Lit for 0.4 sec. + 0.4 sec. × 1
Lights other than above
Lights other than above
Not lit
Not lit
3 OPE-LED
Leuchtet für 1 s × 1
Leuchtet für 1 s × 2
Leuchtet für 1 s × 4
Leuchtet für 1 s × 5
Leuchtet für 1 s × 6
Leuchtet für 1 s × 8
Leuchtet für 1 s × 2
Leuchtet für 0,4 s + 0,4 s × 1
Leuchtet für 0,4 s + 0,4 s × 1
Leuchtet anders als oben beschrieben
Leuchtet anders als oben beschrieben
Leuchtet nicht
Leuchtet nicht